7.  NORMAL OPERATION DISPLAY CODES

5 Boiler Resets in 15 minutes

1. Turn electrical supply to boiler off and on.

2. If the boiler fails to operate please contact Ideal (if under warranty) or alternatively 

a Gas Safe Registered Engineer if outside of the warranty period.  In IE contact a 
Registered Gas Installer (RGII).

False Flame Lockout

Restart the appliance - if the boiler fails to operate then please contact Ideal (if under 
warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty 
period.  In IE contact a Registered Gas Installer (RGII).

DISPLAY CODE ON BOILER

DESCRIPTION

No Water Flow

ACTION

Please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if 
outside of the warranty period.  In IE contact a Registered Gas Installer (RGII).

Check system water pressure is between 1 & 1.5bar on the system pressure gauge.  
To re-pressurise the system see Section 4.  If the boiler fails to operate then please contact 
Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer if outside of the 
warranty period.  In IE contact a Registered Gas Installer (RGII).

8. 

FAULT CODES

Flow Temperature Overheat 
or No Water Flow 

Flow/Return Differential > 
50°C

If the boiler fails to operate then please contact Ideal (if under warranty) or alternatively 
a Gas Safe Registered Engineer if outside of the warranty period.  In IE contact a 
Registered Gas Installer (RGII).

Flame Loss

Ignition Lockout

1. Check other gas appliances in the house are working to confirm a supply is present in 

the property.

2. If other appliances do not work or there are no other appliances, check the gas supply 

is on at the meter and/or pre payment meter has credit.  If the boiler fails to operate then 
please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer 
if outside of the warranty period.  In IE contact a Registered Gas Installer (RGII).

1. Check condensate Pipe for blockages (refer to Section 3)

2. Check other gas appliances in the house are working to confirm a supply is present in 

the property.

3. If other appliances do not work or there are no other appliances, check the gas supply 

is on at the meter and/or pre payment meter has credit.  If the boiler fails to operate then 
please contact Ideal (if under warranty) or alternatively a Gas Safe Registered Engineer 
if outside of the warranty period.  In IE contact a Registered Gas Installer (RGII).

Fan Fault

Restart the appliance - if the boiler fails to operate then please contact Ideal (if under 
warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty 
period.  In IE contact a Registered Gas Installer (RGII).

Flow Thermistor

Restart the appliance - if the boiler fails to operate then please contact Ideal (if under 
warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty 
period.  In IE contact a Registered Gas Installer (RGII).

Return Thermistor

Restart the appliance - if the boiler fails to operate then please contact Ideal (if under 
warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty 
period.  In IE contact a Registered Gas Installer (RGII).

Outside Sensor Failure

Restart the appliance - if the boiler fails to operate then please contact Ideal (if under 
warranty) or alternatively a Gas Safe Registered Engineer if outside of the warranty 
period.  In IE contact a Registered Gas Installer (RGII).

Low Mains Voltage

Contact a qualified electrician or your electricity provider.

Unconfigured PCB

Unconfigured PCB or gas valve short circuit.  Please contact Ideal (if under warranty) 

or alternatively a Gas Safe Registered Engineer if outside of the warranty period.  In IE 
contact a Registered Gas Installer (RGII).

F 5

F 9

L 1

L 2

L 6

L C

F U

L 5

L 9

F 2

F 3

F 6

F 7

F 4

L 4

F 8

Summary of Contents for LOGIC SYSTEM S18IE

Page 1: ...e Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Heating For the very latest copy of literature for specification and maintenance practices visit our website ide...

Page 2: ...erence should be made to the current ETCI rules for electrical installation It is essential that the instructions in this booklet are strictly followed for safe and economical operation of the boiler...

Page 3: ...our boiler efficiently using less gas turn the central heating temperature knob A to the position or lower In winter periods it may be necessary to turn the knob towards the MAX position to meet heati...

Page 4: ...l your Gas Safe Registered engineer Preventative solutions During cold weather set the central heating temperature knob A to maximum Must return to original setting once cold spell is over Place the h...

Page 5: ...grammer are as you require and adjust if necessary Check the programmer external to the boiler is in an ON position and the hot water cylinder thermostat is turned up NO See boiler Operation Modes and...

Page 6: ...central heating but the appliance has reached the desired temperature set on the boiler The boiler is operating in central heating hot water mode The boiler is operating in frost protection 7 NORMAL...

Page 7: ...s Safe Registered Engineer if outside of the warranty period In IE contact a Registered Gas Installer RGII 1 Check condensate Pipe for blockages refer to Section 3 2 Check other gas appliances in the...

Page 8: ......

Reviews: