background image

When replacing any part on this appliance, use only spare parts that you can be assured conform to the safety and performance 

specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Heating.
For the very latest copy of literature for specification and maintenance practices visit our website idealheating.com 

 

where you can download the relevant information in PDF format.

QAA55 ROOM 

THERMOSTAT KIT 

INSTRUCTIONS

H E A T I N G

April 2021

UIN 226216 A02

IMAX XTRA 2

80 120 160 200 240 280

80P 120P 160P 200P 240P

Summary of Contents for QAA55

Page 1: ... copy parts that have not been clearly authorised by Ideal Heating For the very latest copy of literature for specification and maintenance practices visit our website idealheating com where you can download the relevant information in PDF format QAA55 ROOM THERMOSTAT KIT INSTRUCTIONS H E A T I N G April 2021 UIN 226216 A02 IMAX XTRA 2 80 120 160 200 240 280 80P 120P 160P 200P 240P ...

Page 2: ...RODUCTION The following document provides instructions on how to fit a QAA55 Room Thermostat This allows temperature setting of individual heating zones up to a maximum of three zones using the QAA55 Kit Please refer to the installation and servicing manual for guidance on adding the additional heat zones The kits consist of the following parts 1 QAA Room Thermostat UIN 533901589 Shown in Fig 1 2 ...

Page 3: ...diators Use a small flat bladed screwdriver to remove the room thermostat cover as shown in Fig 3 Use a minimum of 2 screws not supplied to fix the Room Thermostat back plate to the wall as shown in Fig 4 Fig 4 Fig 3 Feed the 2 wire cable through the rear or the top of the back plate and connect the wiring as follows 1 Connect the red wire to pin 1 of connector CL BSB Data 2 Connect the black wire...

Page 4: ... to 240V wiring Configuration of the Room Thermostat to the boiler occurs during the configuration process described within the boiler manual 1 Connect the CL BSB Data red wire to pin 1 of connector I10_CN_A 2 Connect the CL BSB Ground black wire to pin 2 of connector I10_CN_A These connections are shown Fig 7 Insert connector I10_CN_A into Installer connector I10A as shown in Fig 8 1 4 CONNECTING...

Page 5: ...wiring Configuration of the Room Thermostat to the boiler occurs during the configuration process described within the boiler manual If the QAA55 Room Thermostat is required to run heating zone 2 connect the wiring to I10_CN_B as follows 1 Connect the CL BSB Data red wire to pin 1 of connector I10_CN_B 2 Connect the CL BSB Ground black wire to pin 2 of connector I10_CN_B These connections are show...

Page 6: ...iring Configuration of the Room Thermostat to the boiler occurs during the configuration process described within the boiler manual If the QAA55 Room Thermostat is required to run heating zone 3 connect the wiring to I10_CN_C as follows 1 Connect the CL BSB Data red wire to pin 1 of connector I10_CN_C 2 Connect the CL BSB Ground black wire to pin 2 of connector I10_CN_C These connections are shown...

Page 7: ...7 IMAX XTRA 2 QAA55 Room Thermostat Kit Instructions ...

Page 8: ...y to find out how See https www gov uk managing your waste an overview for guidance on how to efficiently recycle your business waste Technical Training Our Expert Academy offer a range of training options designed and delivered by our experts in heating For details please contact expert academy co uk Ideal is a trademark of Ideal Boilers Registered Office Ideal Boilers Ltd National Avenue Hull Ea...

Reviews: