18
Installation and Servicing
SECTION 2 - INSTALLATION
Pack B Contents Telescopic
A
Telescopic Flue Terminal
B
Flue Turret
C
Rubber Terminal Wall Seal (external)
D Screw
E
Sealing Tape
F
Wall Seal - White (internal)
D
C
A
E
F
B
Pack B Contents Non-Telescopic
A
Flue Terminal
B
Flue Turret
C
Rubber Terminal Wall Seal (external)
D
Cutting Aid
E
Wall Seal - White (internal)
A
D
B
C
E
UNPACKING CONT’D
2.3 FRONT PANEL REMOVAL
1.
Loosen the 2 screws retaining the front panel at the
underside of the boiler.
2.
Release catches at rear of door by pulling
downwards.
3.
Pull the underside front panel forward then lift
upwards to remove.
1
2
Note.
This flue system incorporates a removable flue outlet nose that utilises a push fit location system. This enables the
installation of deflector, high level or balcony outlet flue kits without the removal of the whole ‘B’ pack terminal. The appliance
must not be operated without the desired outlet nose correctly fitted in place.
Note. Location dimples must be aligned with terminal mounting frame.