Appendix C
Measurement Methods and Limits
C-12
ISO Class F (Category 7)
Measurement Limits in dB
Freq
Attenuation
NEXT
ACR
Power
Sum ACR
( MHz )
Permanent
Channel
Permanent
Channel
Permanent
Permanent
1.0
4.0
4.0
65.0
65.0
61.0
58.0
4.0
4.0
4.1
65.0
65.0
61.0
58.0
10.0
5.4
6.4
65.0
65.0
59.6
56.6
16.0
6.8
8.1
65.0
65.0
58.2
55.2
100.0
17.5
20.8
65.0
62.9
47.5
44.5
250.0
28.4
33.8
60.4
56.9
32.0
29.0
300.0
31.4
37.4
59.2
55.7
27.8
24.8
350.0
34.1
40.6
58.2
54.7
24.1
21.1
400.0
36.7
43.7
57.3
53.8
20.6
17.6
450.0
39.2
46.6
56.6
53.1
17.4
14.4
500.0
41.5
49.4
55.9
52.4
14.4
11.4
550.0
43.8
52.1
55.3
51.8
11.5
8.5
600.0
46.0
54.7
54.7
51.2
8.7
5.7
Measurement Limits in dB
Freq
Power Sum NEXT
ELFEXT
Power Sum ELFEXT
Return Loss
( MHz )
Permanent
Channel
Permanent
Channel
Permanent
Channel
Permanent
Channel
1.0
62.0
62.0
65.0
65.0
62.0
62.0
21.0
19.0
4.0
62.0
62.0
65.0
65.0
62.0
62.0
21.0
19.0
10.0
62.0
62.0
62.7
60.8
59.7
57.8
21.0
19.0
16.0
62.0
62.0
59.3
57.5
56.3
54.5
20.0
18.0
100.0
62.0
59.9
46.0
44.4
43.0
41.4
14.0
12.0
250.0
57.4
53.9
39.2
37.8
36.2
34.8
10.0
8.0
300.0
56.2
52.7
37.8
36.4
34.8
33.4
10.0
8.0
350.0
55.2
51.7
36.7
35.3
33.7
32.3
10.0
8.0
400.0
54.3
50.8
35.7
34.3
32.7
31.3
10.0
8.0
450.0
53.6
50.1
34.8
33.4
31.8
30.4
10.0
8.0
500.0
52.9
49.4
34.0
32.6
31.0
29.6
10.0
8.0
550.0
52.3
48.8
33.3
31.9
30.3
28.9
10.0
8.0
600.0
51.7
48.2
32.6
31.3
29.6
28.3
10.0
8.0