background image

9

Instruction Manual v7.0 Apr 2014

Functions

Taking Your Body Weight Reading

TAKING A READING

Step 1.

Place scale on floor.  This should be a hard, stable, level surface.

Step 2

Step on the scale to begin measuring weight.  The scale will turn on automatically.
 

Step 3. 

After the weight measurement is locked it will be displayed on the screen.  Step off the scale. 

The blue light on the scale will start blinking.  Once communication with an Ideal Life Pod™ has been 

made, the blue light will stop blinking and remain constant.  The screen will blink 3-4 times and a voice (if 
voice volume is not set to “OFF”) will let you know that the measurement has been sent.  A moving “0” will 

appear briefly on the screen.  Do not step on the scale during this time.  The screen will turn off and the 

scale will go into sleep mode.

NOTES

If the scale cannot send a reading, the blue light will turn off.  After one minute the scale will try again. It will 

try to send a reading up to 3 times. If the process still fails after 3 tries, the unsent reading will be stored 
inside the scale.  The scale will turn off and automatically try to send stored readings every hour.  

You can change the displayed weight measurement units, language spoken, and voice volume by using the 
switches on the back of the scale. 

If something goes wrong while taking a reading, you may be presented with an error message.    

1.  “Err1” means that the scale is unable to take a reading due to movement or instability.   Ensure the scale  

    is on a flat surface and try to remain still while taking a reading.

2.  “Err2” means that you have exceeded the maximum weight of the scale.

3.  A low battery icon means that the scale’s batteries are low and need to be replaced.

Functions

Summary of Contents for Body Manager BWM0002

Page 1: ...nal Any instructions for change in treatment and health related information or advice should only be made directly with a healthcare professional Version 7 0 Apr 2014 IDEAL LIFE Body Manager TM BodyWeight Scale Model BWM00020001 INSTRUCTION MANUAL Read before use May be used with IDEAL LIFE Pod sold separately for use with IDEAL LIFE Health Management System ...

Page 2: ...ale 3 Package Contents 4 Location Interference 5 Your IDEAL LIFE Body Manager 6 Your IDEAL LIFE Pod 7 Powering UpYour IDEAL LIFE Body Manager 8 Table of Contents Functions 9 TakingYour Body Weight Reading 9 FactsYou Should Know 10 Care and Maintenance 11 Specifications 12 FCC Statement 13 Service Requirements 14 ...

Page 3: ...asurement of body weight It is intended for use by adults individuals aged 18 and older in a non clinical environment such as in the home as an aid to monitoring body weight It is not intended for the diagnosis of or screening for medical conditions The IDEAL LIFE Body Manager can be used alone to automatically measure your body weight If you would like to transmit information for display on a per...

Page 4: ...NUAL 4 AA BATTERIES FOR YOUR IDEAL LIFE BODY MANAGER ILP 0001 IDEAL LIFE POD IDEAL LIFE POD Optional Accessory NOTE Check your system to be sure that it is in working order and that it contains all parts listed above If either of these conditions is not met please return your system to the place of purchase AC ADAPTER TELEPHONE LINE ETHERNET CORD BWM0002 IDEAL LIFE Body Manager Product may vary fr...

Page 5: ...ended IDEAL LIFE Pod location is NOTE While using an IDEAL LIFE Pod with telephone line connectivity the telephone line will be in use If the telephone line is in use while trying to use your IDEAL LIFE Pod the information will be stored in your IDEAL LIFE Body Manager and will be sent later Away from electrical appliances such as a TV personal computer or a cordless phone In a HIGH and CENTRAL lo...

Page 6: ... AA Batteries Battery Cover Your IDEAL LIFE Body Manager Your IDEAL LIFE Body ManagerTM Battery Compartment Back of Scale Switches for Language Units and Volume Units Switch kg lb st Volume Switch high low off Language switch English Spanish French ...

Page 7: ...isplay AC Adapter Jack USB Port Ethernet Cable RJ45 Jack Connection Battery Cover Telephone Cord RJ11 Jack For Telephone Connection Your IDEAL LIFE Pod Optional Accessory Sealed with an antenna for cellular Internet connectivity Telephone Connection Telephone Cord RJ11 Jack For Line Connection sealed for cellular internet connectivity ...

Page 8: ...ated if batteries are not in the device for an extended period of time Use only new batteries of the required size and the recommended type For best performance and the longest life alkaline batteries are recommended Do not mix different type date or brand name batteries together Be sure to follow the instructions when installing the batteries Since batteries can leak chemicals that damage electro...

Page 9: ...will turn off and the scale will go into sleep mode NOTES If the scale cannot send a reading the blue light will turn off After one minute the scale will try again It will try to send a reading up to 3 times If the process still fails after 3 tries the unsent reading will be stored inside the scale The scale will turn off and automatically try to send stored readings every hour You can change the ...

Page 10: ...n the same area of the scale platform and DO NOT MOVE Should the weight on the scale exceed the scale s capacity you may see an error message displayed Electronic sensors are sensitive Be careful not to drop or hit the scale Place it gently on a flat surface and store it in a safe place The scale is an electronic instrument and should never be submerged in water CAUTION Do not attempt to open the ...

Page 11: ...ance Your scale does not require special maintenance Take care to avoid getting your scale dirty A dampened cloth with water and mild detergent or glass cleaner can be used to wipe down the outside of the scale Your scale is a precision instrument Please handle it with care ...

Page 12: ...ote These specifications are subject to change without notice IDEAL LIFE Pod Optional Accessory Model ILP 0001 Display LED s Power Source AC adapter OperatingTemperature Humidity 50 F to 104 F 10 Cto 40 C Below 85 relative humidity Storage Temperature Humidity 23 F to 122 F 5 C to 50 C Below 90 relative humidity Console Weight Approx 142g without batteries Outer Dimensions Approx 120mm Width x 105...

Page 13: ...ect the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC Rules Operation is s...

Page 14: ...pairs should be performed by our company or an authorized agent It is the responsibility of users requiring service to report the need for service to our company or to one of our authorized agents Please refer to the location you purchased or received your equipment for details of where service can be facilitated through ...

Page 15: ...NAGER IDEAL LIFE GLUCO MANAGER IDEAL LIFE POD IDEAL LIFE Step Manager IDEAL LIFE Breath Manager IDEAL LIFE Direct Connect IDEAL LIFE SpO2 Manager IDEAL LIFE Medication Manager IDEAL LIFE Health Tablet IDEAL LIFE Communication Enabler Caregiver Relief Your Gateway to Health Leveraging the Power of Communication Reinventing Healthcare for an IDEAL LIFE IDEAL LIFE Health Wellness Solution are all pro...