background image

w

w

w

.

id

ea

l

b

o

ile

rs

.c

o

m

H

al

o

 

Co

mb

R

F

 

In

st

a

l

la

ti

o

n

 G

ui

d

e

Summary of Contents for 222140

Page 1: ...w w w i d e a l b o i l e rs com Halo Combi RF I n s t a l l a t i o n G u i d e ...

Page 2: ......

Page 3: ...th the Halo Smart Interface installed in the boiler The Halo Smart Interface plugs into the front aperture on the boiler and communicates to the boiler via OpenTherm The Halo unit is powered by 4 AA batteries and communicates with the Smart Interface through Zigbee a local RF protocol SAFETY INFORMATION The Ideal Halo Combi RF must be installed by a competent person with the appropriate safety qua...

Page 4: ...ensation controller as indicated This product is compatible with the boiler and provides compensation control that has been permanently enabled The boiler has been commissioned in accordance with the manufacturer s instructions which have been supplied to the householder The central heating temperature control knob should normally be set in the mid position Signed Date UIN 223825 A01 Halo Combi RF...

Page 5: ...frames or solid concrete walls If the distance between the Halo and Smart Interface is above 30 metres or the install location is challenging consider using the Ideal Zigbee Booster Product Code 221132 or mounting the Smart Interface externally to the boiler using a bracket Product Code 220366 Further details on this at www idealboilers com 1 2 1 5m 1 Mounted 1 2 1 5m above the floor 2 Not above a...

Page 6: ...using and clip into place 2 If no trim plate is required use the rear housing of the Halo to position the unit on the wall alternatively secure rear housing to trim plate Take care not to overtighten the screws C INSTALLATION OF THE HALO The Halo can be either wall mounted or desk mounted Wall mounting the Halo If there are any concerns regarding signal strength and location of the wall mounted Ha...

Page 7: ...ed rear housing and desk stand 2 Insert the 4 AA batteries provided into the front housing of the Halo Pay close attention that the orientation of the batteries is as indicated in the housing 3 Clip the combined rear housing and desk stand into place ...

Page 8: ...rm connection see diagram On brand new boilers the link should already be in place 2 Locate the wiring terminals 230V connections are on the left and low voltage on the right 3 If existing 230V device is already installed remove wiring from the 230V connections and add the link wire into the room stat timer connection see diagram On brand new boilers the link will already be in this position Link ...

Page 9: ...n the aperture 8 Push fit the Halo Smart Interface into the boiler aperture 5 Locate the blanking plate on the front of the boiler and remove carefully with a small flat bladed screwdriver 6 Remove link wire plug and keep in a safe place Link wire plug Blanking plate ...

Page 10: ...tch off the boiler the Override LED should now go out 11 Press and hold the Pair button on the Smart Interface until the Zigbee LED starts flashing red to begin the pairing process with the Halo 9 Switch on the boiler the Halo Smart Interface will power up and begin setup this can take up to 90 seconds Once setup is complete the green Power LED should be the only LED illuminated ON ...

Page 11: ...g Complete when the Halo has successfully connected to the Smart Interface 5 The device will automatically prompt set up of the time and date 6 There is the opportunity to add an installer contact phone number into the device at this stage if not changed this will default to the Ideal Boilers Customer Service number 7 The home screen will be displayed showing the current and target temperature and...

Page 12: ...the device setup should be set by a competent person Landlord settings Specific settings for landlords SMART INTERFACE LED KEY LED Status Power Green Power ON No illumination No Power Boiler Green Demand No illumination No Demand Connectivity No illumination Cloud configuration not required for Halo Combi RF Zigbee No illumination No Zigbee network Green Zigbee network active Green flashing Identi...

Page 13: ...perature at the time specified OFF Delayed start If the room temperature is close to target temperature the heating start time is delayed to save energy OFF Display tolerance Select the display tolerance of the room temperature this can be set at increments of 0 5 or 0 1 C 0 1 C Temperature offset Fine tune the room temperature display 2 5 to 2 5 C 0 Daylight saving time Automatically move to dayl...

Page 14: ...PRT access via the menu Target RSSI between 0 and 65 and text green On the Halo set the mode to AUTO then increase the temperature to 30 C Flame ON Boiler ON Boiler LED on Smart Interface ON Green On the Halo set the mode to AUTO then decrease the temperature to 5 C Flame OFF Boiler OFF Boiler LED on Smart Interface OFF Check the Smart Interface indication is correct Power LED green Zigbee LED gre...

Page 15: ...erface or are not replacing an existing Halo then press accept In the support page the Zigbee RSSI is lower than 65 and text red Consider moving the Halo closer to the Smart Interface If the situation persists then consider using Zigbee Booster available separately or mounting the Smart Interface externally to the boiler using a bracket further details on www idealboilers com Deleting Halo from th...

Page 16: ...n compliance with Directive 2014 53 EU The full text of the EU declaration of conformity is available at the following internet address www idealboilers com UIN 223827 A02 Ideal Boilers Ltd National Avenue Hull HU5 4JN T 01482 498660 E enquiries idealboilers com RF frequency 2405 2480MHz Max RF output power 10dBm ...

Reviews: