7
Test result of an unshielded 4-pair data cable, standard T-568-B
wiring, tested with 4,6 shorted; screen plays as:
1. When test is in progress “Test” blinks;
fault (shorted at 46) was detected, “Test”
goes off and is replaced by “Fail”. The
third row displays ** at pin numbers 4,6
which was the pin or pair found shorted.
2. Error message “Short 4-6” shown on last
line replacing cable length.
Test result of an unshielded 4-pair data cable, standard T-568-B
wiring, tested with 1,2 Open:
1. When test is in progress “Test” blinks;
when test is completed, error (Open at
1-2) was found, “Test” goes off and
shows ‘Fail’.
2. The wire map shows two missing pin
numbers indicating the open wire;
3. Error message ‘Open 1-2’ appears on the last line.
Test result of an unshielded 4-pair data cable, standard T-568-B
wiring, tested with 7-8 pair mis-wired; screen displays:
1. When test is in progress “Test” blinks;
when completed, error (mis-wired at
7-8) was found, “Test-” goes off and
“Failing-’ shown. The third row
displays pins 12345687, in which
78 pair was found mis-wired.
Test results of an unshielded 4-pair data cable, with all 8 pins
reversely wired; screen plays:
1. When test is in progress “Test”
blinks; when completed, error was
found, “Test” goes off and “Fail”
appears
2. The third row displays pins
87654321 found mis-wired.
3. The forth row displays error message Miswire 1 2 3 6 , Miswire 4 5 7 8 and
repeats.
Fail
RJ45
12345678
No Shield
123*5*78 ID 1
Short
46
Fail
RJ45
12345678
No Shield
345678 ID 1
Open 1-2
Fail
RJ45
12345678
No Shield
123456
87
ID 1
Miswire 78
Fail
RJ45
12345678
No Shield
87654321 ID 1
Miswire 1236
PK Elektronik Vertriebs GmbH, E-Mail: info@pkelektronik.com, Internet: www.pkelektronik.com