22
Measurement
Specifications
Function
Range
Resolution
Accuracy
61-847
±(a%+b)
Temperature
-26ºF to 932ºF
(-32ºC to 500ºC)
0.1
º
±3.6ºF or ±1.8% of reading,
whichever is greater
±1.8ºC or ±1.8% of reading,
whichever is greater
Emissivity
0.1~1.0
0.1
Distance to
Spot Ratio
12:1
NA
Response
Time
≤
250ms(95% of
reading)
Repeatability
1 .5°F or 0.7%,
whichever is
greater
Environmental Specifications
Operating Temperature:
32ºF to 122ºF (0ºC to 50ºC) (<80%RH)
Operating Altitude:
6500 ft (2000 m)
Storage Temperature:
-4ºF to 140ºF (-20ºC to 60ºC) (<80%RH)
Intended for indoor use.
Safety
Summary of Contents for 61-847
Page 7: ...6 7 4 1 3 6 7 2 5 6 8 ...
Page 17: ...16 17 Best Accuracy Coverage Average Accuracy Coverage Poor Accuracy Coverage ...
Page 33: ...32 33 4 1 3 6 7 2 5 6 8 ...
Page 59: ...58 59 4 1 3 6 7 2 5 6 8 ...
Page 78: ...78 Notes ...
Page 79: ...78 79 Notes ...