Contact Removal: 

Removal of the wire crimped contacts from the housing requires a contact removal tool.  The contact 

removal tools are as follows: 

#20 contact  

M81969/14-11    

 

             #12 contact 

M81969/14-04    

 

             #8 contact  

M81969/14-12    

 

To remove a contact, squeeze the insertion/extraction tool, insert it into the appropriate hole from the 
bottom side of the connector, then allow the tool to expand out.  The expanded tool should compress the 
contact retention clips, allowing the contact to be removed with a gentle pull on the wire.  Once the 

contact is disengaged, remove the insertion/extraction tool. 

Note: PCB contacts are not removable from the housing once installed 

 

 

 

Connector Mounting: 

 

A.

 

Panel Float Mounting 
Float mounting on a panel is achieved with the use of shoulder screws.  The shoulder screws used 

should match the following diagram: 
 

 

 

B.

 

Panel Fixed Mounting 

The drawer connectors can be fixed mounted to a panel by means of a screw and washer through 
the mounting slots on the top and bottom of the connector.  No special hardware is required to 
mount the connector in this manner.   

 

 