1S6416 Rev. 1 ECN 2021-0124
Page 2 of 5
Contact Removal:
Removal of the wire crimped contacts from the housing requires a contact removal tool. The contact
removal tools are as follows:
#20 contact
M81969/14-11
#12 contact
M81969/14-04
#8 contact
M81969/14-12
To remove a contact, squeeze the insertion/extraction tool, insert it into the appropriate hole from the
bottom side of the connector, then allow the tool to expand out. The expanded tool should compress the
contact retention clips, allowing the contact to be removed with a gentle pull on the wire. Once the
contact is disengaged, remove the insertion/extraction tool.
Note: PCB contacts are not removable from the housing once installed
Connector Mounting:
A.
Panel Float Mounting
Float mounting on a panel is achieved with the use of shoulder screws. The shoulder screws used
should match the following diagram:
B.
Panel Fixed Mounting
The drawer connectors can be fixed mounted to a panel by means of a screw and washer through
the mounting slots on the top and bottom of the connector. No special hardware is required to
mount the connector in this manner.