24
classic HE P
-
Installation & Servicing
INSTALLATION
FLUE OUTLET
Part No. Description
HE15P
HE18P
n/a
Maximum Flue Length (m)
4
4
201 180
Flue ext. 60/100
3
3
201 189
Terminal Vertical Roof 60/100
1
1
158 431
Weather Collar Pitched Roof
1
1
158 432
Weather Collar Flat Roof
1
1
201 182
90
o
Elbow Kit (60/100)
2
2
201 183
45
o
Elbow Kit (60/100)
2
2
201 867
Vertical Connector Kit
1
1
33 FLUE TERMINAL POSITION
610 mm
min.
ex7531
610 mm
min.
ex7532
The terminal should be positioned so that products of
combustion can safely disperse at all times.
Pluming may occur at the termination so, where
possible, terminal positions where this could cause a
nuisance should be avoided.
Minimum dimensions are shown below
Terminal Position
Minimum Dimension
Directly below an opening,
air brick, windows, etc.
300 mm
Below plastic / painted gutters
300 mm
Painted surface
300 mm
Below eaves or balcony
500 mm
mxhe7686
mxhe7687
34 FLUE ARRANGEMENT
Note.
The equivalent flue length resistance of the 90
o
elbow kit
(60/100) is 1.0m and the 45
o
elbow kit (60/100) is 0.75m.