background image

2

Classic SE RS - 

Users

e.

Under NO circumstances should any of the sealed components
on this appliance be used incorrectly or tampered with.

Minimum clearances

A clearance of 533mm (21") MUST be available at the front of the
boiler for servicing.

The minimum clearances given below MUST be complied with in
order to maintain the safe running of the boiler .

Above the boiler

100 mm

(4")

At each side of the boiler

5 mm

(

1/4

")

Underneath the boiler

100 mm

(4")

In front of the boiler

75 mm

(3")

To light the boiler.

Refer to Frame 1

If a programmer is fitted, refer to separate instructions for the
programmer before continuing.

1.

CHECK THAT THE ELECTRICITY SUPPLY TO THE BOILER IS OFF.

2.

Open the controls access door by hinging downwards.

3.

Ensure that the gas inlet cock (C) is OPEN.

4.

If an overheat thermostat is fitted press the overheat reset button
(D), located as shown in Frame 1.

5.

Switch ON the electricity supply to the boiler. Check that all external
controls, e.g. room thermostat etc., are ON.

6.

Turn the boiler thermostat knob (B) to position 6.  After about 15
seconds the boiler will light automatically - this can be viewed
through the sightglass (A).

Set the boiler thermostat to the desired position.

7.

Close the controls access door.

INTRODUCTION

It is essential that the instructions in this booklet are
strictly followed, for safe and economic operation of
the boiler.

Current Gas Safety (Installation & Use)
Regulations or rules in force.

In your own interest, and that of safety, it is the law that
this boiler must be installed by a CORGI registered installer
or in IE a competent person, in accordance with the above
regulations.

Electricity Supply

This appliance must be efficiently earthed.

Supply: 230 V ~ 50 Hz. 

The fusing should be 3A.

Connection must be made in a way that allows complete
isolation of the electrical supply such as a double pole switch
having a 3mm (1/8") contact separation in both poles, or a
plug and socket, serving only the boiler and system controls.
The means of isolation must be accessible to the user after
installation.

IMPORTANT NOTES

a.

This appliance 

must not be operated

 without the casing

correctly fitted and forming an adequate seal.

b.

If the boiler is installed in a compartment then the
compartment MUST NOT be used for storage purposes.

c.

The ventilation provided for the boiler during installation MUST
NOT be blocked and a check should be made periodically
that the ventilation areas are free from any obstruction.

d.

If it is known or suspected that a fault exists on the boiler then
it MUST NOT be used until the fault has been corrected by a
CORGI registered installer or in IE a competent person.

CAUTION. To avoid the possibility of injury during the installation, servicing or cleaning of
this appliance, care should be taken when handling edges of sheet steel components.

Model

GC Appliance No

Classic

 

SE9 RS ........................... 41 395 44

Classic SE12 RS ......................... 41 395 45
Classic

 

SE15 RS ......................... 41 395 46

Classic SE18 RS ......................... 41 395 99

Classic SE RS  (Natural Gas Models Only)

Summary of Contents for Classic SE9 RS

Page 1: ...NGINEERED FOR PEACE OF MIND When replacing a part on this appliance use only spare parts that you can be assured conform to the safety and performance specification that we require Do not use reconditioned or copy parts that have not been clearly authorised by Ideal Boilers SE9 RS SE12 RS SE15 RS SE18 RS ...

Page 2: ...ation Use Regulations or rules in force In your own interest and that of safety it is the law that this boiler must be installed by a CORGI registered installer or in IE a competent person in accordance with the above regulations Electricity Supply This appliance must be efficiently earthed Supply 230 V 50 Hz The fusing should be 3A Connection must be made in a way that allows complete isolation o...

Page 3: ...card and have a registration number Both should be recorded in your Benchmark Log Book You can check your installer by calling CORGI direct on 01563 72300 THE LOG BOOK SHOULD BE COMPLETED AFTER EACH SERVICE AND KEPT WITH THESE INSTRUCTIONS Caradon Ideal Limited is a member of the Benchmark initiative and fully supports the aims of the programme Benchmark has been introduced to improve the standard...

Page 4: ...a boiler fault contact your gas supplier Boiler is operating satisfactorily for domestic hot water but will not operate for central heating If an external programmer is fitted check that the central heating channel is at an on period Check that the room thermostat is set at the required temperature Test the room thermostat by turning this fully up if this does not respond contact your installer Bo...

Reviews: