Multiple flue kits available.
** Each 90° elbow used is at the expense of 1000mm of straight flue run,
and each 45° elbow is used at the expense of 600mm of straight flue run.
† Typical combined primary and secondary length. See installation instructions
for more details. Note: The Flue Deflector Kit is used at the expense
of 1000mm of straight flue run.
TECHNICAL SPECIFICATION.
17
CODE COMBI
ES 26
CODE COMBI
ES 33
CODE COMBI
ES 38
Weight (packaged) kg
39.5
39.7
39.7
Max installation weight kg
34.7
34.9
34.9
CH output (kW) min/max
@ 70°C
4.8 - 24.2
6.1 - 24.2
7.1 - 24.2
CH output (kW) min/max
@ 40°C
5.1 - 25.6
6.4 - 25.6
7.5 - 25.6
DHW output (kW) max
26.1
32.7
38.2
DHW flow rate l/min.
35°C rise
10.7
13.4
15.7
SEDBUK rating (2005)
91
91.1
91
SEDBUK rating
(2009/2012) %
89.0
89.0
88.9
NOx classification
CLASS 5
CLASS 5
CLASS 5
Adjustable to LPG
No
No
Yes
Condensing boiler
Yes
Yes
Yes
Seasonal space heating
efficiency class
A
A
A
Rated heat output kW
24
24
24
Seasonal space heating
energy efficiency
η
son
%
93
93
93
Sound power level,
indoors L
WA
dB
45
45
44
Water heating energy
efficiency class
A
A
A