HORIZONTAL
FLUE WITH
2 X 45° ELBOW.
NOTE:
Lengths are sum of all straight lengths
between outside edge of turret to
outside wall face.
Numbers of extension D packs give flexibility
of lengths of straight at either side of elbow.
Where extension D packs are cut to length,
flared end connector must be retained.
FLUEING OPTIONS
LOGIC CODE COMBI ES.
62
FLUE
IDEAL
PART NO.
MAXIMUM STRAIGHT
FLUE LENGTH (MM)
Horizontal flue terminal (0.6m long)
+ 2 x Flue elbow 45° kit (60/100)
208171
203131
556
Horizontal flue terminal (0.6m long)
+ 5 x Flue extension 1m (pack D)
+ 2 x Flue elbow 45° kit (60/100)
208171
5 x 203129
203131
5306 (35 max length 4.8m.
+ 2 x 45° elbow)
Horizontal flue terminal (0.6m long)
+ 7 x Flue extension 1m (pack D)
+ 2 x Flue elbow 45° kit (60/100)
208171
7 x 203129
203131
7236 (30 max length 6.8m.
+ 2 x 45° elbow)
Horizontal flue terminal (0.6m long)
+ 8 x Flue extension 1m (pack D)
+ 2 x Flue elbow 45° kit (60/100)
208171
8 x 203129
203131
7800 (12-24 models max length
7.8m. + 2 x 45° elbow)