15
Concord CXi -
Installation
12 CONTROL BOX
Unpack the control box.
1.
Fasten the 2 electrical connections from the overheat
thermostat on the upper front framework to the
terminals marked 'OSTAT' on the plug-in connector
from the gas valve plug lead assembly (polarity not
important.)
2.
Fit the plug-in connector from the gas valve plug lead
assembly to the control box and fasten, using the M4
screws and washers.
3.
Offer up the control box to the RH side of the upper
front framework so that the location buttons on the
back of the control box locate in the slots. Push down
to locate and fasten, using the No.8 screws.
IMPORTANT
4.
Offer up the spark generator assembly to the
combustion chamber base tray and secure the
bracket, using the M5 screws and washers.
Plug the spark generator leads onto the spark
electrode connections on the RH end burner -
access via the side of the combustion chamber.
5.
Ensure the electrical cover is correctly fastened to
the spark generator.