2
Solar Thermal -
Installation and Servicing
general
Max. working excess pressure
6 bar
Max. working temperature
120
o
C
Safety valve
6 bar
Circulation pump
Wilo ST25/7-ECO-3P
Nominal voltage
AC 230 V
Power consumption Pump speed 1
39 W
Pump speed 2
47 W
Pump speed 3
53 W
Max. pump head
7 m
Max. pump capacity
4.5 m
3
/hr
Flow measuring device
2 – 12 l/min
Table 2 - general DaTa - solar pump sTaTion specificaTion
Table 1 - general DaTa - solar collecTor specificaTion
Operating voltage
230 Volt ( + 15%) 50Hz
Internal consumption
< 1W
3 inputs for recording temperatures
PT1000
1 output
Normally open relay, switching power max.800W, fuse:250V 4A MT
Output protected against overload and short circuits
Display
Animated LCD display, 2 colour backlight
Appropriate protection
IP 20/DIN 40050
Operation temperature range
0 to + 45
o
C
Installation
Wall mounting
Weight
250 g
Housing
Recyclable, 3 part plastic housing
Dimensions
L x B x H (mm) 136 x 133 x 37
2 x PT1000
1.5m silicon cable, measuring range up to+ 180
o
C
Table 3 - general DaTa - solar conTroller specificaTion
Model
TS 8000
TS 8001
Size
Collector type
Roof-mounted collector
In Roof-mounted collector
Overall area (m2)
2.02
2.51
Absorber area (m2)
1.84
2.28
Aperture area (m2)
1.91
2.32
L x W x H (mm)
1730 x 1170 x 83
2058 x 1227 x 105
Weight (kg)
35
49
Performance and
Installation
Absorber capacity (l)
1.4
1.7
Housing
Al-frame
Wooden frame
Surface
Al, natural or anodized
(Improved corrosion resistance)
Back plate
Al-sheet
Absorber sheet
Al highly selectively coated
Al, highly selective vacuum coating
Absorption* (%)
95
95
Emission* (%)
5
5
ø manifold (mm)
18 or 22 (¾ or 1")
22 (1")
ø risers (mm)
8
8
Connections
Blank (compression joint),
coupling nut with flat seal
Coupling nut with flat seal
Glass
3.2 mm tempered solar safety glass
3.2 mm tempered solar safety glass
Transmittance of glass (%)
95
90.2
Insulation
40 mm mineral wool plate
50 mm mineral wool plate
Max. stagnation temperature
234˚C under test conditions
234˚C under test conditions
Max. operating pressure
10 bar
10 bar
Aperture area
1.922m²
2.33m²
Conversion factor N
0
0.769
0.776
Heat loss coefficient a
1
3.847W/m²K
3.293W/m²K
Proper heat transfer medium
Polypropylene glycol/water mixture
Polypropylene glycol/water mixture
Approved installation angle min.
15˚, max. 75˚
15˚, max. 75˚
Certificate
EN 1 2975-1.2 SOLAR KEYMARK
sap Data
Ts8000 - on roof
Ts8001 - in roof
Aperture area 1.922m
2
Aperture
Area
2.33m
2
Conversion Factor N
o
0.769
Conversion Factor N
o
0.776
Heat Loss coefficient a
1
3.847W/m
2
K
Heat loss Coefficient a
1
3.293W/m
2
K
Heat Loss coefficient a
2
0.0103W/m
2
K
Heat loss Coefficient a
2
0.011W/m
2
K
207786-2.indd 2
16/02/2012 11:25:35