27.08.2018
17 / 136
EVO S -
Installation and Servicing
3.3.2. G31 Propane Gas (for relevant models)
Nominal power Pn (80/60°C)
kW
Nominal power when condensing P (50/30°C)
kW
Minimal power Pn (80/60°C)
kW
Nominal heat input Qn
kW
Ignition heat input Qall
kW
Minimum heat input Qmin
kW
Gas flow rate at Pn
m
3
/h
CO
2
value ranges
%
Flue-gas mass flow rate (80/60°C)
Qn
Qall
Qmin
g/s
Flue-gas mass flow rate (50/30°C)
Qn
Qall
Qmin
g/s
Flue-gas temperature (80/60°C)
Qn
Qall
Qmin
°C
Flue-gas temperature (50/30°C)
Qn
Qall
Qmin
°C
Inside diameter of flue-gas output
mm
Maximum allowable nozzle pressure
(B23P) (80/60°C)
Qn
Qall
Qmin
Pa
Maximum allowable nozzle pressure
(B23P) (50/30°C)
Qn
Qall
Qmin
Pa
Combustion air flow rate at Qn
m
3
/h
NOx class
Flue-gas removal and air inlet type classifications
EVO S
50
70
95
56,4
69,9
95,7
59,7
75,2
102,3
11,5
31,9
33,5
58,0
72,1
98,5
18,0
32,9
34,5
11,8
32,9
34,5
2,4
3,0
4,0
at Qmin : 9,9 % < CO
2
< 10,1 %
at Qmax : 10,3 % < CO
2
< 10,5 %
26,0
8,1
5,3
32,4
14,8
14,8
44,1
15,5
15,5
25,7
7,9
5,2
31,2
14,6
14,6
44,0
15,3
15,3
78
64
63
69
60
60
75
60
60
60
42
40
47
34
34
56
34
34
80
100
100
200
19
19
105
24
24
138
20
20
177
16
16
93
22
22
129
20
20
73,0
90,7
123,9
6
B23, B23P
C13, C33