26
EVOMAX
-
Installation & Servicing
InStALLAtIon
34 InStALLER ConnECtIonS
In
S
t
ALLA
t
Ion
Permanent 230V
ac
Mains Supply
Optional 230V
ac
Call for CH
Optional 230V
ac
Call for HW
Optional 230V
ac
DHW Pump or Diverter Valve Output
Optional 230V
ac
CH or System Pump Output
Optional 5V OpenTherm
Input
Optional
5V Outside
Sensor
Input
Optional 5V DHW T
ank
Sensor
Input
Optional
0-10V Input
206210-10228
1.
If a Pump is to be run from the boiler and the electrical current draw is 1.3A
inductive or less then the pump can be connected directly into the CH Pump or DHW Pump connections,
as appropriate (e.g. Grundfos 40/60 UPS is satisfactory). If the current draw is more th
an this (eg a Grundfos 40/120 UPS) then an external relay should be operated by the
CH Pump or DHW Pump connections, with the external relay then powering the pump
.
2.
The Lockout V
olt Free Relay contacts will close 4 minutes after a Fault occurs.
3.
The Burner On V
olt Free Relay contacts will close when the Burner is on.
4.
Only Ideal Outside Sensor and DHW
Tank Sensor kits should be connected to the boi
ler
.
5.
The External Interlock and Interlock Relay Contacts connections are only used in conju
nction with the External Interlock Kit.
6.
The Rectifier connections must not be used (only used in the existing internal boiler wi
ring).
7.
The eBus connections are not for use.
206210-3.indd 26