18
FP14KC-X
JAN 2023
CAUTION!
Locking Latches require compressed air pressure of 90 PSI Min to 115 PSI Max for
proper latch operation.
NOTE:
To assemble airline tubing into push fittings, use firm pressure to push tubing into
fitting until it bottoms out. Ensure tubing is cut square with no burrs, Fig 28.
7)
Route and connect D6 Airlines to Lift for Latch operation,
Fig. 27
. Cut D6 airline to connect Air Fitting
to Air Valve. Connect airline from Air Fitting to Air Valve using
‘Inlet’ Valve Port ‘A’,
Figs. 27 A & B
.
Fig. 27
8)
Connect D6 Airline to the
‘Outlet’ Valve Port ‘P’ and route through Flex Tubing to connect to T Fitting.
Connect airlines to each end of T-Fitting, then connect to Y Fittings in Crossbeams,
Figs. 27, 27-A &-B.
Fig. 27-A Fig. 27-B
Fig. 28
Runway
Airline (D6)
Runway Airline (D6)
(Route thru Metal Rings)
LH Power Side Runway
Y Fitting
(Route Airline thru Hole in
Crossbeam to Y Fitting)
T Fitting
Y Fitting
Air Cylinder
Air Cylinder
Air Valve
Airline (D6)
(See Details) Figs. 27 A & B
‘Inlet’
D6 Airline to
Air Valve
‘Outlet’
D6 Airline to
T Fitting
‘Quick
Disconnect’
Air Fitting
Air Valve
(Push Button)
D6
Airline
Push
Sleeve
Airline
‘Push’
Fitting
Air Valve
Crossbeam
‘Inlet’
Port
‘Outlet’
Port