INSTALLATION
29
IMAX XTRA -
Installation & Servicing
Info Mode
32 STANDARD CONTROLS ACCESS CONT'D
I N F O
P A R A
Press
Display
I N F O
Actual Flow Temperature T1 (
o
C)
Press
Display
Description
Actual Return Temperature T2 (
o
C)
1. 2 1
2. 2 1
3. - 3 6
OUTSIDE Temperature T4 (
o
C)
(-36 displayed if outside sensor kit not fitted)
4. - 3 6
N/A
FLUE GAS Temperature T5 (
o
C)
Set Flow Temperature (
o
C)
5. 7 0
6. 8 2
7. 0. 0
Rate of Return Temperature Rise (
o
C/s)
8. 0. 0
Rate of Flow Temperature Rise (
o
C/s)
9. 0. 0
N/A
A. - 3 6
N/A
Flashing
Info mode is entered from standby mode by pressing the 'mode' button twice.
Press the step button until the desired information is displayed. The dot after the 1st digit will be flashing indicating the
Module is in 'info' mode. No settings can be changed in 'info' mode.
continued...........
INST
ALLA
TION