LT 8000 Series: Quick Reference Card - 1

6510-30- 0326  Rev. A

I.  Display and Remote Handsets

13

15

16

14

17

18

19

20

21

22

23

25

24

1

14 15

2

3

4

5

6

7

9

10

11

8

12

16

13

1.   Graphical Display

14. Talkset Jack

2.   Option Keys 

15. DB-9 Serial Port

3.   Autotest Key

16. DC Input Jack

4.   Arrow Keys

17. Pass LED

5.   Wiremap Key

18. Fail LED

6.   Length Key

19. Testing LED

7.   Enter Key

20. Talk LED

8.   Alphanumeric Keys

21. Tone LED

9.   Escape Key

22. High Voltage LED

10. Cable Selection Key

23. No Patch Cable LED

11. Backlight Key

24. Battery Level LED’s

12. On/Off Switch

25. Tone switch

13. Connector Port

II.  Soft Keys

Okay or confirm an action.

Stop or cancel an action.

Print data.

Save data using Auto Increment naming convention.

Overwrite or rename data.

Run the selected test in continuous mode (real time).

Page-up for information.

Soft Keys (Continued)

Page-down for information.

Select/Deselect an item in a list box.

Select an action item.

Activate/Deactivate the Talk Set option.

Delete characters.

III.  Ready Screen

1

2

3

4

5

6

7

8

9

10 11 12

13 14

15

16

Screen Indicators

1.   Memory Usage

5.   Time and Date

2.   Battery Meter or AC Cable

6.   Setting

3.   Talk Set Indicator

7.   Label

4.   Screen Title

8.   Label

Screen Functions

9.   Cable ID

13. Instrument Information

10. Test Record

14. Analyze

11. Field Calibration

15. Talk Set Select

12. Preferences

16. Help

IV.  Tester Calibration

A calibration screen will always appear 24 hours after the last
field calibration.

1.  To recalibrate the tester, connect the DH and RH end-to-

end using the Field Calibration Adapter.

2.  From the DH 

Tools

 screen, select the 

Field Calibration

icon.

Tester Calibration (Continued)

1.  Press the 

Tone Key

 on the RH.

2.  Select the 

Run

 option on the DH.

If the calibration was successful, remove the Field Calibration
Adapter.

If the calibration was unsuccessful, refer to the 

User’s Guide

,

Chapter 3, Tester Field Calibration

.

V.  Tester Configuration

Most tester configuration parameters are set from the
Preferences screen

1.  From the Tools screen, select the 

Instrument 

  

Icon.

The Preferences screen displays.

2.  Use the 

Arrow

 keys to select one of the following

configuration options:

- User Information

- Autotest Preferences

- Display Contrast

- Time-out Options

- Measurement Units

- PC & Printer I/F

- Talkset Option

- Date & Time

- Display Language

- Factory Defaults

- Clear Memory

3.  Enter new configuration parameter(s) as required.

VI.  Cable Type Selection

1.  Press the 

Cable Selection

 

 hard key.

2.  Press 

Enter 

 

to select a cable type and its associated

default NVP for testing.

3.  Position the cursor and press 

Enter 

 to change to a

new cable type and its associated default NVP for testing.

Note:

 

A number of unique cable manufacturer NVP values

are stored in the tester memory. To access the list of
manufacturer cables for the currently highlighted test
standard, press the 

 soft key.

4.  If you want to use the selected cable as the basis for a

Custom Cable, press the 

 soft key

5.  Change the default cable features and save the cable as a

new Custom Cable.