background image

General Specifications

V connector:

1100 Vp                           AC+DC
850 Vp  m            m

AC+DC

LV

Ω Ω

•             )(   Hz% DF °C°F

Temperature coefficient:

0.1 X (Spec. Accuracy) per °C, <18°C or >28°C

Battery Life:

100 hours typical (alkaline)

Physical Characteristics

Dimensions:

200mm x 90mm x 42mm
212mm x 100mm x 55mm (w/holster)

Weight (w/battery):

0.4Kg

Weight (w/holster):

0.6Kg

Enviornmental Characteristics

Temperature Operating:

0 to +50°C

Temperature Non-Operating:

-20 to +60°C

Humidity (Operating):

<80% R.H.

Altitude (Operating):

2,222m (7290 ft.)

Altitude (Non-Operating):

12,300m (40354 ft.)

Vibration & Shock (Operating):

MIL-T-28800E Type II Class 5
2.66g RMS, 5 to 500 Hz, 
3 axes, (10 min. each)

Dust/Water Protection IP Rating:

IP 64

Certifications & Compliances

Safety:

Designed to IEC 1010-1, UL3111 and CSA 

Specifications Input Rating:

1000VDC Category II
600VDC Category III
750VAC Category II
600VAC Category III

Overvoltage Category:

Cat III:  Distribution level mains, fixed installations

Cat II:  Local level mains, appliances, portable equipment
Cat I:  Signal level, special equipment or parts of equipment, 
telecommunication, electronics

Pollution Degree 2:

Do not operate in environments where conductive pollutants may be 
present.

16

15

Continuity Check

To Verify Continuity:

A continuity test ensures that all circuit connections
are intact.  
1. Plug the Black test lead into the COM port and the Red test lead into the V

Hz port.

2. Set the rotary switch to the            position.
3. Press the blue button until            is shown in the display.
4. Connect the test leads to the circuit to be measured.  The buzzer will sound if the resistance of the circuit

measured is lower than 50

.

Continuity threshold:  Approx. 50

Continuity Indicator:  2kHz tone buzzer
Input protection:  600V rms

General Specifications

Stated accuracies are at 23°C +5°C at less than 80% RH and without battery indicator displayed.
LCD display digits:

4-1/2 or 3-3/4

Bargraph segements:

42 segment graph

Display count

20,000 or 4,000

Numeric update rate:

2 times/sec (20,000 count)

Bargraph:

20 times/sec

Polarity display: 

Automatic

Overrange display:

OL is displayed

Low voltage indicator:            

is indicator

Automatic power-off time:

Automatic backlit off = 15 minutes

Power source

One 9V dry cell battery

Maximum input voltage:

1000V (750VAC) Cat II between V and COM

Maximum floatin voltage:

1000V (750VAC) Cat II between any terminal and earth ground

Maximum input current:

200mA between mA and COM 10A continuous between A and COM 
(20A for 30 seconds)

Maximum open circuit

600V between A and COM and 

Voltage (current inputs):

between mA and COM

Overload protection mA

1A (600V) fast blow fuse connector:

A connector:

15A (600V) fast blow fuse

C

US

Summary of Contents for ND 2351-1

Page 1: ...Rotary Function Switch 5 Input Connectors WARNING 1 DO NOT UNDER ANY CIRCUMSTANCES EXCEED THESE RATINGS Voltage is not to exceed 1000 Volts Resistance Capacitance Logic and Continuity functions are no...

Page 2: ...surements 2 To avoid electrical shock hazards and or damage to the meter Do not exceed the voltage ratings for the meter Use caution when measuring voltage Do not use during electrical storms AC power...

Page 3: ...he range button while in AC voltage measurements for 2 seconds enables the dB dBm func tion While in dB dBm mode pressing the range button toggles between dB and dBm dB dBm Function The reading of dB...

Page 4: ...r off The meter turns itself off within 30 minutes if no controls or settings are changed Restore power by switching dial Power up Options Press button while turning meter on from OFF position Light b...

Page 5: ...50 500Hz 1kHz 1 2 80 1 2 80 10A 40Hz 500Hz 1mA 0 8 50 0 8 50 500Hz 1kHz 1 2 80 1 2 80 1kHz 3kHz 2 0 80 2 0 80 Voltage Burden 800mV max for mA input 1V max for A input Input Protection Equipped with h...

Page 6: ...tion 4 Press the blue button to choose between and LV LV setting reduces the maximum test voltage level to about 0 5V to avoid turning on semiconductor devices 11 Frequency and Duty Factor Measurement...

Page 7: ...e that the device being tested contains no voltage 4 Press the blue button to chose between a C or F display Multiply the accuracy by 2 for F Input protection 600V rms Note The readings 360 C on 1 C r...

Page 8: ...y A continuity test ensures that all circuit connections are intact 1 Plug the Black test lead into the COM port and the Red test lead into the V Hz port 2 Set the rotary switch to the position 3 Pres...

Page 9: ...test leads from the front terminals and turn the meter off 2 Remove the screw from the battery cover and lift to remove 3 Remove the battery 4 Remove the three screws connecting the top and bottom ca...

Page 10: ...om abuse neglect accident unauthorized repair alteration or unreasonable use of the instrument Any implied warranties arising out of the sale of an IDEAL product including but not limited to implied w...