background image

2

#61-482

480 Platinum Pro Series

Commercial Contractor 
Grade Multimeter

True RMS

Symbols in this Manual

This symbol indicates where cautionary or other 

information is found in the manual.

Fuse
Battery

Refer to Figure 1 and to the following numbered steps to 
familiarize yourself with the meter’s front panel controls 
and connectors.

True RMS

1

4

2

3

5

8

11

12

9

6

10

7

Summary of Contents for ND 2366-1

Page 1: ...mbols in this Manual This symbol indicates where cautionary or other information is found in the manual Fuse Battery Refer to Figure 1 and to the following numbered steps to familiarize yourself with...

Page 2: ...C Voltage Current in the Voltage Current mode or to measure Resistance or Continuity or Diode in mode or to measure frequency or RPM in Hz RPM mode WARNING 1 DO NOT UNDER ANY CIRCUMSTANCES EXCEED THES...

Page 3: ...verload Protection Function Overload Protection VAC VDC 1000V AAC ADC 1A 500V 16A 500V Ohms 600VAC 600VDC Diode 600VAC 600VDC Continuity 600VAC 600VDC Unit of Measure Multipliers For your reference th...

Page 4: ...Burden 40mA 10 A 40 00 2 0 5 200mV max 400mA 0 1mA 400 0 2Vmax 10A 10mA 10 00 2 5 5 2V max AC Conversion Type AC conversions are AC coupled true RMS responding calibrated to the RMS value sine wave in...

Page 5: ...RPM is shown on the display 4 Connect the meter in parallel with the load or circuit 5 Measure Frequency or RPM 10 9 DC Current Range Resolution Max Accuracy Voltage Display Burden 40mA 10 A 40 00 0...

Page 6: ...sure resistance True RMS Circuit Connection Range Guide for Ohms 400 Meter indicates actual resistance 4k Multiply meter display reading by 1 000 to acquire actual resistance 40k Multiply meter displa...

Page 7: ...Resistor value is 620 000 Ohms 620k with a tolerance of 5 Blue Red Yellow Gold Temperature Temperature Accuracy Temperature Accuracy 4 F 32 F 2 8 F 20 C 0 C 2 4 C 33 F 212 F 1 6 F 1 C 100 C 1 3 C 213...

Page 8: ...Hz port 3 Set the rotary switch to the position 4 Press the blue button until is shown on the display 5 Connect the test leads to the diode Normally the forward voltage drop of a good silicone diode i...

Page 9: ...ce of the circuit measured is lower than 30 True RMS Circuit Connection Peak Hold Measurements Function Range Accuracy Function Range Accuracy DC Voltage 400mV Unspecified AC Voltage 400mV Unspecified...

Page 10: ...e indicated positive implied Overrange Indication OL or OL Low Battery Indication when the battery voltage drops below operating voltage Size WxHxD 88mm x 180mm x 33 5mm without holster 94mm x 188mm x...

Page 11: ...battery cover and lift to remove 3 Remove the screws from the bottom case and the inside of the battery cover and lift the case bottom until it unsnaps from the case top 4 Remove the defective fuse by...

Page 12: ...m abuse neglect accident unauthorized repair alteration or unreasonable use of the instrument Any implied warranties arising out of the sale of an IDEAL product including but not limited to implied wa...