INSTALLATION
REAR FLUE OUTLET
15 CUTTING THE FLUE - Wall thicknesses up to 600mm (23
5/8
")
1.
The flue cut length is
calculated as detailed in Frame
10.
2.
Measure from the groove and
mark the tube.
3.
To ensure the tube is cut
square, mark the flue all the
way round. using (e.g). a long
straight strip of paper with its
ends overlapped.
4.
Cut to length, using the
cardboard support aid.
5.
Remove the cardboard support
and any burrs.
For flue lengths greater than 600mm (23
5/8
") refer to Frames 30 to 32 -
Flue Extension Ducts
16 FITTING THE FLUE
1.
Attach the clamping/sealing rings to the flue (this prevents the
assembly being pushed right through the hole and causing an
accident).
2.
Pass the cut flue through the prepared hole, ensuring that the
groove is uppermost.
3.
Pull the flue back to compress the rubber seal and fix in place with
the clamping/sealing rings.
Note.
To facilitate turret fixing or removal do
NOT
make good the wall.