IDEATEC S.A. - Z.I. de Noville-les-Bois - rue Léopold Génicot 19A - 5380 Fernelmont, Belgium - Tel: +32(0)81 42 00 10 - Fax: +32(0)81 57 91 70 - E-mail: info@ideatec.be
User’s guide DLC4000/DLC8000 -
Doc. V2.1 - Firmware V3.1
Page 17
Identification des éléments
Description des éléments
Description du produit
11.
&
B5
B6
B3
B7
B8
B2
B4
B1
0
1
3
4
3X
4X
2
3X
2X
3X
1X
B5
B6
B3
B7
B8
B2
B4
B1
B5
B6
B3
B7
B8
B2
B4
B1
B5
B6
B3
B7
B8
B2
B4
B1
IN 2 -
IN 2 -
Operation & Configuration (continued)
SELECTION FLASHES DESCRIPTION
Key B2 is a momentary push button and activates the positive output 1 / negative output
2 when it is pressed and positive output 2 / negative ouput 1 is OFF when key B2 is
released.
Negative input 2 is not used.
Key B2 is a switch and activates the positive output 2 / negative output 1.
Key B2 is the Slave key by default.
Negative input 2 is not used.
Key B2 is not available and the positive output 2 / negative out 1 are permanent positive
outputs.
Key B2 is a switch in Slave mode and activates the positive output 2 / negative output 1.
Key B2 working is conditioned by the negative input2 (handbrake signal). If the signal is
present on negative input 2 the key B2 is disabled and cannot be activated until the
signal is still present.
Key B2 is not automatically activated if the signal on negative input 2 disapears.
Key B2 is a switch in Slave mode and activates the positive output 2 / negative output 1.
Key B2 working
is not
conditioned by the negative input2 (handbrake signal).
10.5.2. Key B2 and negative input 2 configuration.
By default the key B2 is a switch in Slave mode and controls the positive output 2 / negative ouput 1.
It’s possible to disable the key B2 and to put a black pictogram on the key to notify the user of the console that the key
is not available.
When the key is not available then the positive output 2 / negative output 1 are permanent outputs.
Some functions of the negative input 2 are also configured by B2 key in configuration mode 1.
i
In order to avoid configuration mistakes, it is impossible to configure B2 key in
slave mode if the key B1 is disabled. It is also impossible to disable Key B1 if
the key B2 is already configured in slave mode.
11.5. DLC4000/DLC8000 Configuration - MODE 1 (continued)