One safety-related input with two input channels with antivalent behavior (magnetic switch with NO
at S12 and NC at S13):
If the level at terminal S12 is logically 0 and the level at terminal S13 is logically 1, the safety-related
input is activated.
Timing diagram for one safety-related input with two input channels with antivalent behavior:
1 = Activation, transition to operating state Run: Outputs Energized
2 = Deactivation, transition to operating state Run: Outputs Deenergized (defined safe state)
Truth table for one safety-related input with two input channels with antivalent behavior:
Identical signal states are only permissible within the synchronization time
).
Otherwise, identical signal states trigger an alert.
The truth table applies to the wiring diagrams presented for the application functions.
If the magnetic switch in the wiring example above is used for guard monitoring, this means that
the magnetic switch is presented in the activated state and the guard is closed.
Consult the manual of the sensor/device you want to use for your application function for details
on signal state required for activation and deactivation as defined in the present document.
Signal State
at S#2
Signal State
at S#3
Activation State and Operating State
0
1
Safety-related input channel activated, operating state Run: Outputs
Energized
1
0
Safety-related input channel deactivated, operating state Run: Outputs
Deenergized
Summary of Contents for HR6S-S
Page 1: ...http www idec com HR6S S Safety Module Original instructions HR9Z B2202 ...
Page 8: ...8 HR9Z B2202 8 2020 ...
Page 14: ...14 HR9Z B2202 8 2020 ...
Page 20: ...Introduction 20 HR9Z B2202 8 2020 ...
Page 56: ...Installation 56 HR9Z B2202 8 2020 ...
Page 92: ...Accessories Service Maintenance and Disposal 92 HR9Z B2202 8 2020 ...