background image

B-1908-1(0)

INSTRUCTION SHEET - HS1L Series 

Solenoid Type Safety Switch, Inside Connector type

( 2 / 6 )

2016.08

3

Mounting Examples

• Install the interlock switch on the immovable machine or guard, and install the 

actuator on the movable door.  Do not install both interlock switch and actuator on 

the

 

movable door, otherwise the angle of insertion of the actuator to the safety switch 

may become inappropriate, and failure will occur.

(

Examples of Mounting on Hinged Doors

)

Door

 HS1L

Safety Switch

HS9Z-A1S

Actuator

Lock

Door Stop

Hinged

Door

HS1L

Safety Switch

Latch

HS9Z-A2S

Actuator

HS9Z-A1S

Actuator

(

Examples of Mounting on Sliding Doors

)

• L-shaped actuator : HS9Z-A2S

• Adjustable actuator : HS9Z-A3S

When using the safety switch for a hinged door, the minimum radius of the applicable 

door is shown in the following figures.

Minimum Radius

270mm

Door Hinge

Minimum Radius

450mm

Door Hinge

When  he center of the hinged door is 

on the extension line of the contact 

surface of actuator and safety switch.

(

Minimum Radius

510mm

Door Hinge

Minimum Radius

840mm

Door Hinge

When the center of the hinged 

door is on  he extension line of the 

actuator mounting surfase.

(

Minimum

Radius

80mm

Door Hinge

Minimum

Radius

50mm

Door Hinge

When the center of the hinged door is on 

the  extension line of the contact surface 

of actuator and safety switch.

(

When the center of the hinged door is 

on the extension line of the actuator

mounting surfase.

(

Minimum Radius of Hinged Door

• As shown below, the mounting reference position of the actuator inserted into the 

safety switch is the actuator cover or stop film touches the safety switch lightly. (After 

mounting the actuator, remove the actuator cover or stop film from the actuator.)

• Mounting tolerance of the actuator is 0.5mm 

from the center of the actuator to up, down, 

right, and, left.

• Make sure the actuator can be inserted into 

the entry slot wi hout any issue.

• Actuator can move 3.3mm (HS9Z-A1S and 

-A2S) / 2.6mm (HS9Z-A3S) from the mounting 

reference position without affecting the contact 

operation. 

• When closing the door, the actuator is inserted 

and locked within approx. 3.8mm (HS9Z-A1S 

and -A2S) / 3.3mm (HS9Z-A3S) from the 

mounting reference position. 

Actuator Mounting Reference Position

Actuator Mounting Tolerance

HS9Z-A1S                          

Actuator

Cover

Safety Switch

Door Stop

Door Stop

Actuator

Cover

Safety Switch

Safety Switch

HS9Z-A2S

HS9Z-A3S

Stop film

3 3/ 2.6mm

+

Deviation of

Deviation of

actuator position 

                door position

±0.5mm

±0.5mm

Center

Center

Safety 

Switch

HS9Z-A1S

and -A2S

HS9Z-A3S

2.6mm

3.3mm

HS9Z-A1S

and -A2S

HS9Z-A3S

Approx.

3.8mm

Approx.

3.3mm

Recommended Screw Tightening Torque

For mounting the safety switch (M5 screw) *7

For mounting the actuator

HS9Z-A1S, HS9Z-A2S (M5 screw) *7 *8

HS9Z-A3S (M6 screw)
For mounting the lid (M4)

Terminal screw (M3)

Connector

Angle adjusting screw of HS9Z-A3S

  (M3 Hexagon Socket Head Screw)

Screw Tightening Torque

3.2 to 3.8 N•m

2.7 to 3.3 N•m

4.5 to 5.5 N•m
0.9 to 1.1 N•m

0.6 to 0.8 N•m

2.7 to 3.3 N•m

0.8 N•m

CAUTION

*7 When the torque is not enough to recommended screw tightening torque, make 

sure that the screw do not become loose by using adhesive sealants etc. to 

keep right operation and mounting positioning.

*8 When rubber cushions (and spacers) are not used, 

use M6 screws and tighten to a torque of 4.5 to 5.5 

N•m.

Rubber Cushions

• Break a desired knockout to mount a connector using a 

hammer and a screwdriver. 

• Remove the connector lock nut from inside the safety 

switch before breaking the knockout to open a connector 

hole. 

• When breaking the knockout to open a connector hole, be 

careful not to damage the internal contact block.

Note : Cracks or burrs on the connector hole will degrade the 

waterproof characteristics.

Opening the Connector Hole

• Using the angle adjusting screw (M3 hexagon 

socket head screw), the actuator angle can be 

adjusted up to 20°.

• The larger the actuator angle, the smaller the appli-

cable radius of the door swing. After installing the 

actuator, open the door. Then adjust the actuator 

angle so that the actuator enters the entry slot of 

the safety switch properly. 

• After adjusting the actuator angle, apply loctite or the like on the adjusting screw to 

prevent loosening.

Adjusting the Angle Adjustable Actuator (HS9Z-A3S)

20°

Angle adjusting 

screw

CAUTION

The figures shown above are based on the condition that the actuator enters and 

exits the actuator entry slot smoothly when the door is closed or opened. Since 

there may be deviation or dislocation of the hinged door, make sure of correct 

operation in the actual application before installation.

Summary of Contents for HS1L Series

Page 1: ...y 100 000 operations min 900 operations hour Rated Load 900 operations hour 24V AC DC 0 1A Resistive Load 1 000 000 operations min IP67 IEC60529 Degree of Protection 100A 250V Conditional short circuit current Solenoid Indicator Shock Resistance Vibration Resistance Fzh 3 000N minimum F1max 3 900N minimum GS ET 19 2 3 4 Ratings approved by safety agencies 1 TÜV rating AC 15 250V 2 5A DC 13 30V 2 5...

Page 2: ...from the mounting reference position Actuator Mounting Reference Position Actuator Mounting Tolerance HS9Z A1S Actuator Cover Safety Switch Door Stop Door Stop Actuator Cover Safety Switch Safety Switch HS9Z A2S HS9Z A3S Stop film 3 3 2 6mm Deviation of Deviation of actuator position door position 0 5mm 0 5mm Center Center Safety Switch HS9Z A1S and A2S HS9Z A3S 2 6mm 3 3mm HS9Z A1S and A2S HS9Z A...

Page 3: ...ors will cause a break down of the safety switch Solenoid Indicator has polarity Besure to wire correctly Fully press down on the lock nut of the safety switch so they are not lifting or rattling when tightening the connector Tighten it carefully so that there is no gap between the connector and safety switch A L shaped wrench attached to the safety switch Type HS9Z T1 A A To ensure safety make su...

Page 4: ...d in factory for safety circuit inputs Use terminals 11 42 or 21 52 for safety circuit inputs I 50 2 60 2 II Wire Length L mm Through Conduit Port Wire Length inside the Safety Switch I II C D E view B A Cable side applicable connector L Safety Switch Conduit hole connector When wiring the terminal number on each contact is identified by connector number The following shows the identification of t...

Page 5: ... of the circuit Safety relay module HR1S AF series manufactured by IDEC CORPORATION Used as open close monitor of guard Used as lock unlock monitor Output Circuit S1 HS1L DQ4 Safety Switch with Solenoid S2 Starting Switch HW Series Momentary S3 Unlocking Enabling Switch S4 Safety limit Switch ESC Outside start condition K3 4 Safety Contactor F1 Outside fuse of safety relay module at power supply l...

Page 6: ... this declaration relates is in conformity with the EC Directive on the following standard s or other normative document s In case of alteration of the product not agreed upon by us this declaration will lose its validity Applicable EC Directive Low Voltage Directive 2014 35 EU Machinery Directive 2006 42 EC Applicable Standard s EN 60947 5 1 GS ET 19 Type HS9Z A3S HS9Z A1S 33 88 4 104 7 5 2 49 5 ...

Reviews: