15. Deceleration time
This setting specifies the time to decrease the pulse frequency.
Set the time between 10 and 10,000 ms in increments of 1 ms. The first digit of the setting is handled as zero. For example, if
144 is entered, the set value is handled as 140 ms.
16. Trigger to start monitoring origin input
Specifies the timing to start the origin signal monitor.
17. Reversible control enable
Selects the reversible control method from the following reversible control modes when
ZRN mode 1
is selected for 9. Zero
return method. (This is an example when ZRN1 is used with the All-in-One CPU module.)
The outputs used on the FC6A Series MICROSmart vary based on the instruction used, the combination of the pulse output
mode and reversible control, and the model used.
Note:
The outputs (pulse output and reversible control output) used by ZRN instruction cannot be used by other instructions simultaneously.
18. Control direction
When reversible control is enabled, store 0 in this data register for forward operation and store 1 in this data register for reverse
operation.
Timing
Description
Proximity signal OFF
→
ON
After the proximity signal changes from off to on, the change from off to on in the origin signal is monitored.
Proximity signal ON
→
OFF
After the proximity signal changes from off to on and then next changes from on to off, the change from off
to on in the origin signal is monitored.
Reversible Control Enable
Operation
Pattern
Reversible control disabled
Select this option when using pulse output in a single
direction. Pulse A and pulse B can be used independently.
Reversible control
Single-pulse
output
Pulse A is used as pulse output. Pulse B on/off is used as
reversible control.
Reversible control
Dual-pulse
output
Pulse A is used as forward pulse (CW) output.Pulse B is
used as reverse pulse (CCW) output.
Command
Operating Condition
Output Used
All-in-One CPU Module
CAN J1939 All-in-One CPU
Module/Plus CPU Module
Pulse Output
Reversible
Control Output
Pulse Output
Reversible
Control Output
ZRN1
Reversible control disabled
Q0
—
Q0
—
Reversible control Single-pulse output mode
Q0
Q2
Q0
Q1
Reversible control Dual-pulse output mode
Q0, Q1
—
Q0, Q1
—
ZRN2
Reversible control disabled
Q1
—
Q2
—
Reversible control Single-pulse output mode
Q1
Q3
Q2
Q3
Reversible control Dual-pulse output mode
—
—
Q2, Q3
—
ZRN3
Reversible control disabled
Q2
—
Q4
—
Reversible control Single-pulse output mode
—
—
Q4
Q5
Reversible control Dual-pulse output mode
—
—
Q4, Q5
—
ZRN4
Reversible control disabled
Q3
—
Q6
—
Reversible control Single-pulse output mode
—
—
Q6
Q7
Reversible control Dual-pulse output mode
—
—
Q6, Q7
—
Q0
Q0
Q2
Q0
Q1
Summary of Contents for MICROSmart FC6A Series
Page 1: ...B 1726 7 FC6A SERIES Ladder Programming Manual ...
Page 8: ...Preface 7 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Page 32: ...1 OPERATION BASICS 1 20 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Page 96: ...3 INSTRUCTIONS REFERENCE 3 18 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Page 130: ...4 BASIC INSTRUCTIONS 4 34 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Page 192: ...9 SHIFT ROTATE INSTRUCTIONS 9 12 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Page 272: ...12 DISPLAY INSTRUCTIONS 12 24 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Page 284: ...14 REFRESH INSTRUCTIONS 14 6 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Page 502: ...25 DATA LOG INSTRUCTIONS 25 22 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Page 546: ...26 SCRIPT 26 44 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...
Page 598: ...APPENDIX A 14 FC6A SERIES MICROSMART LADDER PROGRAMMING MANUAL FC9Y B1726 ...