SE2L User’s Manual (SE9Z-B1865)
128
18
If the muting function is configured, the override function
is terminated when the override period exceeds the
specified override period
19
If the muting function is configured, the muting is
terminated when muting period exceeds the specified
maximum muting period
20
If the reference monitoring function is configured,
displacement of the reference boundary structures or SE2L
should cause the OSSD to switch to OFF-state when
displacement exceeds the allowable tolerance. This is
applicable especially if the angle of approach exceeds ±30º
from the detection plane
21
Safety relay life span is still valid
22
If the area sequence function is configured, OSSD switches
to OFF-state if area switching sequence is different than
the configured sequence.
This manual only suggests the basic steps for the inspection and maintenance.
User should perform additional inspection and maintenance if necessary.
User should follow necessary steps in accordance to the working environment.
Perform all the inspections mentioned in this manual when using the SE2L for the
first time.
Summary of Contents for SE2L-H05LPC
Page 1: ...SE9Z B1865 SE2L Series Safety Laser Scanner User s Manual...
Page 100: ...SE2L User s Manual SE9Z B1865 99 Figure 7 31 b Function Figure7 31 c Area...
Page 143: ...SE2L User s Manual SE9Z B1865 142 13 External dimension 13 1 SE2L H05LP mm...
Page 144: ...SE2L User s Manual SE9Z B1865 143 13 2 SE2L H05LPC mm...
Page 145: ...SE2L User s Manual SE9Z B1865 144 13 3 Base mounting bracket mm...
Page 146: ...SE2L User s Manual SE9Z B1865 145 13 4 Rear mounting bracket mm...
Page 147: ...SE2L User s Manual SE9Z B1865 146 13 5 Simple base mounting bracket mm...
Page 149: ...SE2L User s Manual SE9Z B1865 148 13 7 Simple rear mounting bracket Long type mm...
Page 150: ...SE2L User s Manual SE9Z B1865 149 13 8 Cover Protection Bracket mm...