SE2L User’s Manual (SE9Z-B1865)
135
72 Operating
temperature
error
Make sure that operating
temperature is within
specification.
Restart the power supply
74-79 Power
supply
error
Make sure that voltage is within
the specification.
Restart the power supply
7C
OSSD excess current error
Make sure the OSSD load is
within the specification.
Restart the power supply
7D
Slave unit 1 error
Check the error code on slave
unit 1
Automatic recovery or Input
reset (During Interlock
setting)
7E
Slave unit 2 error
Check the error code on slave
unit 2
Automatic recovery or Input
reset (During Interlock
setting)
7F
Slave unit 3 error
Check the error code on slave
unit 3
Automatic recovery or Input
reset (During Interlock
setting)
80
Master unit error
Check the error code on master
unit
Automatic recovery or Input
reset (During Interlock
setting)
84-85
Object in limited detection
zone or contamination on
the optical window.
Refer to chapter 8.5 for
cleaning the optical window.
Remove the object or clean the
optical window.
Automatic recovery or Input
reset (During Interlock
setting)
86 Mutual
interference
error
Mount SE2L at a location free
from mutual interference.
Refer to chapter 5.2 mutual
interference for counter
measures.
Automatic recovery or Input
reset (During Interlock
setting)
8F
SD card detection error
Check SD card file or check the
specification of the SD card.
Automatic recovery or Input
reset (During Interlock
setting)
95-9A
OSSD diagnostic error
Check the OSSD output wire.
Restart the power supply
A6 EDM1
input
connection
error
Check the EDM1 input wire.
Restart the power supply
A7 EDM2
input
connection
error
Check the EDM 2 input wire.
Restart the power supply
A9
Reset input error
Check the RESET input wire.
Restart the power supply
AA
Reference monitor error
Check for the displacement of
reference structure or SE2L
position
Automatic recovery or Input
reset (During Interlock
setting)
B1-C0
Optical window is
contaminated
Refer to chapter 8.5 for
cleaning the optical window
Automatic recovery or Input
reset (During Interlock
setting)
C1
Optical window is
removed or contaminated
Replace or clean the optical
window
Restart the power supply
Summary of Contents for SE2L-H05LPC
Page 1: ...SE9Z B1865 SE2L Series Safety Laser Scanner User s Manual...
Page 100: ...SE2L User s Manual SE9Z B1865 99 Figure 7 31 b Function Figure7 31 c Area...
Page 143: ...SE2L User s Manual SE9Z B1865 142 13 External dimension 13 1 SE2L H05LP mm...
Page 144: ...SE2L User s Manual SE9Z B1865 143 13 2 SE2L H05LPC mm...
Page 145: ...SE2L User s Manual SE9Z B1865 144 13 3 Base mounting bracket mm...
Page 146: ...SE2L User s Manual SE9Z B1865 145 13 4 Rear mounting bracket mm...
Page 147: ...SE2L User s Manual SE9Z B1865 146 13 5 Simple base mounting bracket mm...
Page 149: ...SE2L User s Manual SE9Z B1865 148 13 7 Simple rear mounting bracket Long type mm...
Page 150: ...SE2L User s Manual SE9Z B1865 149 13 8 Cover Protection Bracket mm...