SE2L User’s Manual (SE9Z-B1865)
30
3.7.3.1 Automatic restart
SE2L will restart automatically when interlock function is disabled or only the start interlock function is
enabled. When obstacle from the protection zone is removed, OSSD signals switch from OFF-state to
ON-state automatically. OSSD response times for ON and OFF states are configurable (See section 3.12).
However, if SE2L is in the lockout state due to error,
OSSDs will remain in OFF-state even if the interlock
function is disabled.
Figure 3-15 Timing chart of automatic restart
In automatic restart configuration OSSD will automatically switch to ON state after
the object is removed. Confirm the safety while removing the object.
Configured response time should be sufficient for the machine or AGV to stop safely.