SE2L User’s Manual (SE9Z-B1865)
32
3.7.3.3 Manual start (Interlock enabled)
Start interlock is a function which keeps the OSSD in OFF-state during the start-up until an external
reset input is applied. Start interlock setting has only manual mode. The RES_REQ signal switches to
ON-state after the SE2L completes initial routines and ready to accept the RESET input. When RESET input
is applied, OSSD will switch to ON state if no object is detected in the protection zone. The duration of the
reset input should be more than 500ms. Figure 3-17 shows the sequence of start interlock. Delay can be
configured in the range of 1s to 6s.
Figure 3-17 Manual start sequence
3.8 External device monitoring (EDM) function
EDM is a function that monitors the state of the input signal from the controlled machine or automated
guided vehicle (AGV). EDM is configured using the SLS Project Designer. When EDM function is enabled,
any fault detected in EDM signal will switch the OSSD signal to OFF-state. Logic of EDM signal should be
always inverse of the OSSD signal. EDM input signal ON/OFF delay is configurable to match the user’s
system. Figure 3-18 and 3-19 below shows the EDM circuit and EDM timing chart respectively.
Figure 3-18 EDM circuit
Summary of Contents for SE2L-H05LPC
Page 1: ...SE9Z B1865 SE2L Series Safety Laser Scanner User s Manual...
Page 100: ...SE2L User s Manual SE9Z B1865 99 Figure 7 31 b Function Figure7 31 c Area...
Page 143: ...SE2L User s Manual SE9Z B1865 142 13 External dimension 13 1 SE2L H05LP mm...
Page 144: ...SE2L User s Manual SE9Z B1865 143 13 2 SE2L H05LPC mm...
Page 145: ...SE2L User s Manual SE9Z B1865 144 13 3 Base mounting bracket mm...
Page 146: ...SE2L User s Manual SE9Z B1865 145 13 4 Rear mounting bracket mm...
Page 147: ...SE2L User s Manual SE9Z B1865 146 13 5 Simple base mounting bracket mm...
Page 149: ...SE2L User s Manual SE9Z B1865 148 13 7 Simple rear mounting bracket Long type mm...
Page 150: ...SE2L User s Manual SE9Z B1865 149 13 8 Cover Protection Bracket mm...