SE2L User’s Manual (SE9Z-B1865)
57
4.7 Area protection (Mobile, Horizontal, Single Protection, Encoder Input)
When increment encoder is used, area can be switched depending on the speed of AGV (Figure 4-15).
High speed
Medium speed
Low speed
Figure 4-15 Example of AGV’s scanning area depending on the speed (Top view)
4.8 Area protection (Mobile, Horizontal, 2 Units Interconnected, Variable
Area)
For AGVs travelling in both directions, it is possible to use 2 interconnected units of SE2L, each
mounted at front and back. Safety can be improved by switching each unit to monitor the area with
appropriate size and shape based on the speed and direction of travel. Further it is also possible to use
increment encoder in such systems for area switching.
Protection zone
Warning zone 1
Warning zone 2
Summary of Contents for SE2L-H05LPC