SE2L User’s Manual (SE9Z-B1865)
94
Table 7-12 Function
Tab
Item
Description
Sensing
Check to enable the sensing function
Min detection width
*
1
(mm) 30 (Default), 50, 70
Active areas
*
2
: Area 1 to Area 32 (Default)
Area input delay :30ms (Default), 120ms, 270ms, 1s,2s
Operation mode : Protection 1 + Warning 1/2, Protection 1, 2
EDM
Check to enable the EDM function
On delay(ms): 90 (Default), 120, 300
Off delay(ms): 300 (Default), 330, 360
* In dual protection mode, EDM1 and EDM2 can be configured
independently.
Interlock
Check to enable the Interlock function
Start/Restart mode : Manual/Automatic, Manual/Manual
Delay(s): 1(Default) to 6
* In dual protection mode, interlock can be independently configured
for protection zone 1 and protection zone 2.
Reference monitor
Check to enable the Reference monitor function
Tolerance(mm): 100 (Default) to 10000
Muting
Check to enable the Muting function
Muting input sequence:
Muting 1
Muting 2 (Default), Muting 2
Muting 1 (Protection zone 1)
Muting 3
Muting 4 (Default), Muting 4
Muting 3 (Protection zone 2)
Time interval between inputs(s): 1(Default), 3, 5, 10
Max. muting period(min): 1(Default), 6, 12 and Infinity
Max. override period(min): 1(Default), 6,12
* In dual protection mode, muting can be independently configured for
protection zone 1 and protection zone 2.
Area sequence
*
3
Check to enable the Area sequence function
The check box of the area sequence possible area will be valid
The check box for all area will be valid
Master Slave
Check to enable Master Slave function
Current device
*
4
: Master, (Default) Slave1, Slave2, Slave3
Slave count : 1 (Default) to 3 (For Master only)
Use own OSSD outputs (For slave only)
Function
Encoder Input
Check to enable the Encoder Input function
Error tolerance : 0 to 45 %
Encoder pulse 1 : 50 to 1000 (count/cm)
Encoder pulse 2 : 50 to 1000 (count/cm)
Select patterns: Each pattern can be selected from Not Use,
Use as
Static input and Use as Encoder input.
Detailed area setting for each pattern.
For the encoder input set speed division count and area for each speed
range. It is not possible to select same area for two different speeds.
For static input, select the area and enable or disable speed monitoring.
If speed monitoring is enabled it is necessary to provide the speed
range.
*1: The minimum width of detectable objects. Detection is not possible if configured width is more than the
object intended to be detected.
Summary of Contents for SE2L-H05LPC
Page 1: ...SE9Z B1865 SE2L Series Safety Laser Scanner User s Manual...
Page 100: ...SE2L User s Manual SE9Z B1865 99 Figure 7 31 b Function Figure7 31 c Area...
Page 143: ...SE2L User s Manual SE9Z B1865 142 13 External dimension 13 1 SE2L H05LP mm...
Page 144: ...SE2L User s Manual SE9Z B1865 143 13 2 SE2L H05LPC mm...
Page 145: ...SE2L User s Manual SE9Z B1865 144 13 3 Base mounting bracket mm...
Page 146: ...SE2L User s Manual SE9Z B1865 145 13 4 Rear mounting bracket mm...
Page 147: ...SE2L User s Manual SE9Z B1865 146 13 5 Simple base mounting bracket mm...
Page 149: ...SE2L User s Manual SE9Z B1865 148 13 7 Simple rear mounting bracket Long type mm...
Page 150: ...SE2L User s Manual SE9Z B1865 149 13 8 Cover Protection Bracket mm...