SE2L User’s Manual (SE9Z-B1865)
123
8. Inspection and maintenance
Inspection and maintenance are necessary for safety operation. User must ensure the inspection and
maintenance are carried out as specified in the user’s manual.
Before performing inspection and maintenance, confirm the following items.
The machine or AGV monitored by SE2L is switched OFF.
The surrounding of working environment is safe.
8.1 Pre-operation inspection
After configuring the SE2L the authorized user should perform pre-operation inspection using a test piece.
It should be performed without connecting the sensor to the system.
Table 8-1 Pre-operation inspection list example
Condition
No.
Check item
Yes No
Remark
1
SE2L is correctly mounted at the intended location and
screws are firmly fastened
2
All the wirings are correct
3
The OSSD signal switches from ON state to OFF state
when the test piece is placed inside the protection zone
4
The OSSD signal remains in the OFF state when the test
piece is moved inside the protection zone
5
The OSSD signal switches from OFF state to ON state
when the test piece is removed from the protection zone
6
Area is switched and correctly displayed on SE2L when
the input signals are changed according to the area
switching table
7
If SE2L is in automatic restart mode, OSSD signal
switches from ON-state to OFF-state when the test piece is
placed inside the protection zone and switches from
OFF-state to ON-state when the test piece is removed
8
If SE2L is in manual restart mode, OSSD signal switches
from ON-state to OFF-state when the test piece is placed
inside the protection zone and remains in OFF-state when
the test piece is removed
9
If the start interlock function is configured, starting the
SE2L without placing the test piece in protection zone
causes the OSSD signal to remain in OFF-state until the
RESET signal is provided
Once the configuration is completed, make sure to remove the SD card from SE2L
and close the protective cap properly. Failure to do so may result in product
malfunction and/or affect its sealing performance.
Summary of Contents for SE2L Series
Page 1: ...SE9Z B1865 SE2L Series Safety Laser Scanner User s Manual ...
Page 100: ...SE2L User s Manual SE9Z B1865 99 Figure 7 31 b Function Figure7 31 c Area ...
Page 143: ...SE2L User s Manual SE9Z B1865 142 13 External dimension 13 1 SE2L H05LP mm ...
Page 144: ...SE2L User s Manual SE9Z B1865 143 13 2 SE2L H05LPC mm ...
Page 145: ...SE2L User s Manual SE9Z B1865 144 13 3 Base mounting bracket mm ...
Page 146: ...SE2L User s Manual SE9Z B1865 145 13 4 Rear mounting bracket mm ...
Page 147: ...SE2L User s Manual SE9Z B1865 146 13 5 Simple base mounting bracket mm ...
Page 149: ...SE2L User s Manual SE9Z B1865 148 13 7 Simple rear mounting bracket Long type mm ...
Page 150: ...SE2L User s Manual SE9Z B1865 149 13 8 Cover Protection Bracket mm ...