SE2L User’s Manual (SE9Z-B1865)
124
10
If the muting function is configured, SE2L terminates the
muting (OSSD switches to OFF-state) when the test piece
is placed inside the protection zone other than the muting
area even though the muting conditions are fulfilled.
11
If the muting function is configured, SE2L does not switch
to mute state when the muting input sequence is different
than the specified sequence.
12
If the muting function is configured, SE2L does not switch
to mute
state when the time interval between two muting
inputs exceeded the specified time interval
13
If the muting function is configured, the override function
is terminated when the override period exceeds the
specified override period
14
If the reference monitoring function is configured,
displacement of the reference boundary structures or SE2L
should cause the OSSD to switch to OFF-state when
displacement exceeds the allowable tolerance. This is
applicable especially if the angle of approach exceeds ±30º
from the detection plane
15
If the area sequence function is configured, OSSD switches
to OFF-state if area switching sequence is different than
the configured sequence.
Note: Stop using the SE2L when any check item is marked NO.
8.2 Operation inspection
This test should be performed after completing the pre-operation inspection. It must be performed by taking
the sufficient safety measures.
Performing this inspection before pre-operation inspection may damage the
system leading to critical injury or death.
Table 8-2 Operation inspection list example
Condition
No.
Check item
Yes No
Remark
1
The OSSD signal switches from ON-state to OFF-state and
the machine or vehicle stops when the test piece is placed
inside the protection zone
2
The OSSD signal remains in OFF-state and the machine or
vehicle stops when the test piece is moved inside the
protection zone especially at the border
Do not modify or dissemble SE2L during inspection as this will affect its detection
capability leading to critical injury or death.
For the traceability, it is recommended to retain and store the maintenance and
inspection records.
Summary of Contents for SE2L Series
Page 1: ...SE9Z B1865 SE2L Series Safety Laser Scanner User s Manual ...
Page 100: ...SE2L User s Manual SE9Z B1865 99 Figure 7 31 b Function Figure7 31 c Area ...
Page 143: ...SE2L User s Manual SE9Z B1865 142 13 External dimension 13 1 SE2L H05LP mm ...
Page 144: ...SE2L User s Manual SE9Z B1865 143 13 2 SE2L H05LPC mm ...
Page 145: ...SE2L User s Manual SE9Z B1865 144 13 3 Base mounting bracket mm ...
Page 146: ...SE2L User s Manual SE9Z B1865 145 13 4 Rear mounting bracket mm ...
Page 147: ...SE2L User s Manual SE9Z B1865 146 13 5 Simple base mounting bracket mm ...
Page 149: ...SE2L User s Manual SE9Z B1865 148 13 7 Simple rear mounting bracket Long type mm ...
Page 150: ...SE2L User s Manual SE9Z B1865 149 13 8 Cover Protection Bracket mm ...