SE2L User’s Manual (SE9Z-B1865)
126
Table 8-3 Daily inspection list example
Condition
No.
Check item
Yes No
Remark
1
The OSSD signal switches from ON state to OFF state
when test piece is placed inside the protection zone
2
The OSSD signal remains in OFF state when the test piece
is moved inside the protection zone
3
The OSSD signal switches from OFF state to ON state
when the test piece is removed from the protection zone
4
If the SE2L is in automatic restart mode, OSSD signal
switches from ON-state to OFF-state when the test piece is
placed inside the protection zone and switches from
OFF-state to ON-state when the test piece is removed
5
If the SE2L is in manual restart mode, OSSD signal
switches from ON-state to OFF-state when the test piece is
placed inside the protection zone and remains in OFF-state
when the test piece is removed
6
If the start interlock function is configured, starting the
SE2L without placing the test piece in protection zone
causes the OSSD signal to remain in OFF-state until the
RESET signal is provided
7
If the muting function is configured, SE2L terminates the
muting (OSSD switches to OFF-state) when the test piece
is placed inside the protection zone other than the muting
area even though the muting conditions are fulfilled.
8
If the muting function is configured, SE2L does not switch
to mute state when the muting input sequence is different
than the specified sequence.
9
If the muting function is configured, SE2L does not switch
to mute state when the time interval between two muting
inputs exceeds the specified time interval
10
If the muting function is configured, the override function
is terminated when the override period exceeds the
specified override period
11
If the reference monitoring function is configured,
displacement of the reference boundary structures or SE2L
should cause the OSSD to switch to OFF-state when
displacement exceeds the allowable tolerance. This is
applicable especially if the angle of approach exceeds ±30º
from the detection plane
12
If the muting function is configured, SE2L terminates the
muting if muting period exceeds the specified maximum
period
13
If the area sequence function is configured, OSSD switches
to OFF-state if area switching sequence is different than
the configured sequence.
Contamination on the optical window switches the OSSD signal to OFF state.
Summary of Contents for SE2L Series
Page 1: ...SE9Z B1865 SE2L Series Safety Laser Scanner User s Manual ...
Page 100: ...SE2L User s Manual SE9Z B1865 99 Figure 7 31 b Function Figure7 31 c Area ...
Page 143: ...SE2L User s Manual SE9Z B1865 142 13 External dimension 13 1 SE2L H05LP mm ...
Page 144: ...SE2L User s Manual SE9Z B1865 143 13 2 SE2L H05LPC mm ...
Page 145: ...SE2L User s Manual SE9Z B1865 144 13 3 Base mounting bracket mm ...
Page 146: ...SE2L User s Manual SE9Z B1865 145 13 4 Rear mounting bracket mm ...
Page 147: ...SE2L User s Manual SE9Z B1865 146 13 5 Simple base mounting bracket mm ...
Page 149: ...SE2L User s Manual SE9Z B1865 148 13 7 Simple rear mounting bracket Long type mm ...
Page 150: ...SE2L User s Manual SE9Z B1865 149 13 8 Cover Protection Bracket mm ...