Check if seal is attached on the surface of the optical window.
Check the direction to insert the optical window and cover slowly from above. Avoid shaking the
optical components.
Confirm that optical window is correctly attached to the body without any inclination.
Use torque wrench to tight the 4 screws 1 to 4.
Confirm that appearance of the SE2L is not abnormal before installing it back to original system.
After installing in the system, adjust the optical window as explained in section 8.6.2.
8.6.2 Adjustment of the optical window
During the operation SE2L constantly monitors the transmittance of optical window. When it decreases
due to contamination SE2L reports an error. Therefore, it is necessary to measure the initial transmittance of
the new optical window and save it into the device. Contamination should not be present while performing
this adjustment..
<Adjustment steps>
a) Use adjustment software “Optical Window Adjuster” included in the CD. Create a local folder and save
the application into it. Log file generated during the process (format “serial_number_time.log”) and the
adjustment data (format “serial_number_time.csv”) are saved in the same folder where the application is
saved. Retain these files for reference and troubleshooting.
b) Supply the power to SE2L and connect with the PC through USB cable.
c) Start Optical Window Adjuster. Window as shown in figure 8-2 will appear.
Figure 8-2 Optical Window Adjuster
Optical window is a critical part of SE2L therefore it should not be contaminated or
scratched during the replacement.
Replace the optical window at clean environment to avoid dust particles from
entering the device affecting the detection capability.
Avoid touching the internal parts of SE2L as it may contaminate them decreasing the
detection capability.
After replacing the optical window it is necessary to apply the adjustment SE2L is
ready to use only after completing the adjustment.
Summary of Contents for SE2L Series
Page 1: ...SE9Z B1865 SE2L Series Safety Laser Scanner User s Manual ...
Page 100: ...SE2L User s Manual SE9Z B1865 99 Figure 7 31 b Function Figure7 31 c Area ...
Page 143: ...SE2L User s Manual SE9Z B1865 142 13 External dimension 13 1 SE2L H05LP mm ...
Page 144: ...SE2L User s Manual SE9Z B1865 143 13 2 SE2L H05LPC mm ...
Page 145: ...SE2L User s Manual SE9Z B1865 144 13 3 Base mounting bracket mm ...
Page 146: ...SE2L User s Manual SE9Z B1865 145 13 4 Rear mounting bracket mm ...
Page 147: ...SE2L User s Manual SE9Z B1865 146 13 5 Simple base mounting bracket mm ...
Page 149: ...SE2L User s Manual SE9Z B1865 148 13 7 Simple rear mounting bracket Long type mm ...
Page 150: ...SE2L User s Manual SE9Z B1865 149 13 8 Cover Protection Bracket mm ...