SE2L User’s Manual (SE9Z-B1865)
134
SE2L is interlocked
Check the configuration of the interlock function. If
RES_REQ is ON, supply SE2L with RESET signal
Table 9-2 shows the error number of the SE2L. These numbers are displayed on the 7-segment display of
SE2L. If SE2L is unable to resume the normal operation,
contact the nearest distributor or sales
representative for support.
Table 9-2 Error number list
Error number
Details
Possible reason
Solution suggestion
45 Setting
error/Incomplete
setting
Reconfigure SE2L
Automatic recovery or Input
reset (During Interlock
setting)
56
Invalid area error
Confirm the input status during
area switching.
Automatic recovery or Input
reset (During Interlock
setting)
57
Area Input Connection
Error
Confirm the input status during
area switching.
Automatic recovery or Input
reset (During Interlock
setting)
59
Area sequence error
Confirm area switching
sequence.
Automatic recovery or Input
reset (During Interlock
setting)
5B
Encoder speed error
Make sure the encoder speed is
correctly configured
Automatic recovery or Input
reset (During Interlock
setting)
5C Encoder
error
Confirm the encoder input
status.
Automatic recovery or Input
reset (During Interlock
setting)
5D
Encoder speed error
Make sure the encoder speed is
correctly configured
Automatic recovery or Input
reset (During Interlock
setting)
5E
Invalid area error
(During Encoder is valid)
Confirm the input status during
area switching.
Automatic recovery or Input
reset (During Interlock
setting)
5F
Encoder speed error
Make sure the encoder speed is
correctly configured
Automatic recovery or Input
reset (During Interlock
setting)
60-63
Motor error
Mount the sensor in a way that
the vibration, bump stated in
the specification does not
exceed
.
Automatic recovery or Input
reset (During Interlock
setting)
64 Master-Slave
communication error
Confirm the connection
between master and slave.
Automatic recovery or Input
reset (During Interlock
setting)
70 Optical
interference/High
reflective background
Mount SE2L at a location free
from light interference. Refer to
chapter 5.1 for light
interference counter measures.
Automatic recovery or Input
reset (During Interlock
setting)
Summary of Contents for SE2L Series
Page 1: ...SE9Z B1865 SE2L Series Safety Laser Scanner User s Manual ...
Page 100: ...SE2L User s Manual SE9Z B1865 99 Figure 7 31 b Function Figure7 31 c Area ...
Page 143: ...SE2L User s Manual SE9Z B1865 142 13 External dimension 13 1 SE2L H05LP mm ...
Page 144: ...SE2L User s Manual SE9Z B1865 143 13 2 SE2L H05LPC mm ...
Page 145: ...SE2L User s Manual SE9Z B1865 144 13 3 Base mounting bracket mm ...
Page 146: ...SE2L User s Manual SE9Z B1865 145 13 4 Rear mounting bracket mm ...
Page 147: ...SE2L User s Manual SE9Z B1865 146 13 5 Simple base mounting bracket mm ...
Page 149: ...SE2L User s Manual SE9Z B1865 148 13 7 Simple rear mounting bracket Long type mm ...
Page 150: ...SE2L User s Manual SE9Z B1865 149 13 8 Cover Protection Bracket mm ...