2 Operation confirmation
Menu
4 Appendix
1 Overview
3-5
Menu item descriptions
z
Scanner settings
This screen is for checking and changing communication unit settings.
You can configure advanced settings such as communication unit RS-232 settings and Ethernet settings.
(1)
(2)
(3)
(4)
(5)
(8)
(6)
(7)
(9)
(10)
(11)
(12)
(13)
(14)
Edit area
No.
Name
Description
(1) +
Displays the major and minor items on the configuration items list.
(2) -
Displays only the major items on the configuration items list.
(3) Configuration items list
This list is for checking and changing communication unit settings. For details on the
settings, check the configuration items table in the user's manual.
(4) Message output 3
Displays a description of the configuration item.
File operation
No.
Name
Description
(5) Send
Reflects the changed setting values in the communication unit operation.
(6)
Receive
Displays the setting values set on the communication unit in configuration items list
(3).
(7) Clear
Clears the setting values displayed in configuration items list (3) from the screen.
(8) Load
Loads the setting values from the setting value region (non-volatile).
(9) Save
Saves the setting values to the setting value region (non-volatile).
(10)
Initial
Resets the communication unit to the factory defaults. Returns the communication
unit to the factory state. (When advanced settings (14) is enabled)
(11) Reset
Resets the communication unit power supply.