background image

1-1

Overview

Explains an overview of WB9Z-CU100 Support Tool and cautions for use.

1. 1  Overview

"WB9Z-CU100 Support Tool" is software for configuring the communication unit and checking its operation.

1. 2  Usage precautions

In order to use the support tool correctly, please be aware of the following precautions. 

 

z

When the communication unit and the WB9Z-CU100 Support Tool are connected, do not turn off the communication 
unit power supply. 
The WB9Z-CU100 Support Tool may be forcibly terminated. 
After stopping the connection between the communication unit and the WB9Z-CU100 Support Tool, turn off the com-
munication unit power supply. 

 

z

When the communication unit and the WB9Z-CU100 Support Tool are connected, do not allow the computer to enter 
sleep mode. The WB9Z-CU100 Support Tool may be forcibly terminated. 
If the communication unit and the WB9Z-CU100 Support Tool are connected and left for a long period of time, config-
ure the computer so that it does not enter sleep mode. 

 

z

Do not run multiple instances of the WB9Z-CU100 Support Tool at the same time. The support tool may not operate 
correctly.

Summary of Contents for WB9Z-CU100

Page 1: ...B 1968 0 Communication Unit Supporting Code Scanner WB9Z CU100 Support Tool User s Manual...

Page 2: ...damage loss of profit business interruptions loss of business infor mation and other monetary damages that occurs from the use or the inability to use this WB9Z CU100 support tool even if IDEC is inf...

Page 3: ...direct or indirect 2 PROHIBITIONS 2 1 You may not permit other individuals to use the Software except under the terms listed above modify translate re verse engineer decompile disassemble except to th...

Page 4: ...ins the entire agreement between the parties pertaining to the licensing of this software and supersedes all prior agreements and understandings Revision of this agreement is only performed in writing...

Page 5: ...dinthismanual The general terms abbreviations and terminology used in this manual are as follows Item Definition Communication unit Indicates WB9Z CU100 Control character ASCII code 00H 1FH 7FH In thi...

Page 6: ...communication unit Explains about support tool B 1945 Instruction Sheet WB2F 2D Code Scanner Included with the product B 1946 Instruction Sheet WB9Z CU100 Communication Unit Included with the product...

Page 7: ...2 2 WB9Z CU100 Support Tool setup 2 2 2 2 1 Installing the WB9Z CU100 Support Tool 2 2 2 2 2 Uninstalling the WB9Z CU100 Support Tool 2 2 2 3 Operation confirmation method 2 3 2 3 1 Installing the de...

Page 8: ...ation confirmation 3 Menu 4 Appendix 1 Overview vii Contents 4 Appendix 4 1 4 1 Troubleshooting 4 1 4 1 1 The communication port is not displayed 4 1 4 2 ASCII Code Table 4 2 Index A 1 Revision histor...

Page 9: ...0 Support Tool may be forcibly terminated After stopping the connection between the communication unit and the WB9Z CU100 Support Tool turn off the com munication unit power supply z z When the commun...

Page 10: ...ts Item Details Computer PC AT or compatible OS Windows 7 32 64bit Windows 8 32 64bit Windows 8 1 32 64bit Windows 10 32 64bit CPU 1 0 GHz or higher Memory 1 GB or higher Hard disk 100 MB or higher Sc...

Page 11: ...click wb9z cu100_support_tool exe inside the wb9z cu100_support_tool_001 000 00 a folder to run the support tool The support tool may not run correctly if the files in the folder are deleted or moved...

Page 12: ...atest device driver installer from the IDEC website and use it to the install the device driver For details on the installer check the readme that is included with the installer IDEC website URL http...

Page 13: ...ng the IP address 1 Select the communication port that the Communication Unit is connected to 2 1 4 How to check the communication port z z For Windows 7 1 Click Start right click Computer and click P...

Page 14: ...he communication port is not displayed in the communication port on the Connection Settings screen Close the WB9Z CU100 Support Tool and cycle the power supply to the communication unit then start the...

Page 15: ...cquired it will be returned as the response The following shows an example Example ASCII display example netipa Request Click the Get IP address 192 168 001 100 Response IP address 192 168 001 100 suc...

Page 16: ...nit and the computer Control command Displays the screen for sending control commands to the communication unit Scanner settings Displays the screen for checking and changing the communication unit se...

Page 17: ...u item descriptions 3 2 1 File z z Connection setting load Loads a saved connection settings file Only XML is supported as the file extension z z Connection setting save Saves the current connection s...

Page 18: ...reen is initially displayed 1 2 3 4 5 6 7 8 9 10 11 13 12 No Name Description 1 Com port Selects the communication port You can select a valid port 2 Communication speed Not used 3 Data length 4 Parit...

Page 19: ...ASCII display mode 3 HEX Sets the communication monitor to the hexadecimal display mode 4 Clear Clears the communication monitor 5 Get MAC address Gets the MAC address Sends the Get MAC address contro...

Page 20: ...ngs check the configuration items table in the user s manual 4 Message output 3 Displays a description of the configuration item File operation No Name Description 5 Send Reflects the changed setting...

Page 21: ...e No 6 The setting values set on the communication unit are displayed in configuration items list 3 z z Sending setting values 1 After receiving the setting values edit them in the edit area 2 After y...

Page 22: ...he firmware is available on the IDEC website http www idec com 1 3 2 4 5 No Name Description 1 Check version You can check the communication unit firmware version 2 Get Firmware Version You can get th...

Page 23: ...you want to update with in firmware selection No 3 2 Click Start Update No 4 Starts updating the firmware 3 Follow the on screen instructions When firmware is updated all setting value of communicatio...

Page 24: ...ered in hexadecimal values 6 Priffix ON Automatically adds the communication command prefix 7 Suffix ON Automatically adds the communication command suffix 8 Prefix entry field Enter the prefix to set...

Page 25: ...upport Tool display language to Chinese 3 2 5 Help z z User s manual Displays the WB9Z CU100 Support Tool user s manual this manual z z Version information Displays version information The version inf...

Page 26: ...zed in Device Manager Check communication port to which the communication unit is connected in Device Manager Is the device driver installed Check that the device driver has been correctly installed I...

Page 27: ...10011 DC4 20 14 00010100 NAK 21 15 00010101 SYN 22 16 00010110 ETB 23 17 00010111 CAN 24 18 00011000 EM 25 19 00011001 Character Decimal Hexadeci mal Binary SUB 26 1A 00011010 ESC 27 1B 00011011 FS 28...

Page 28: ...01011001 Z 90 5A 01011010 91 5B 01011011 92 5C 01011100 93 5D 01011101 94 5E 01011110 _ 95 5F 01011111 96 60 01100000 a 97 61 01100001 b 98 62 01100010 Character Decimal Hexadeci mal Binary c 99 63 0...

Page 29: ...lling the device driver 2 3 Installing the WB9Z CU100 Support Tool 2 2 J Japanese 3 10 L Language 3 10 M Menu items list 3 1 O Operation confirmation method 2 3 Overview 1 1 R Receiving and sending se...

Page 30: ...A 2 Revision history Edition Published Revised content Page Points 1st 2017 5...

Page 31: ...IDEC CORPORATION All Rights Reserved C The specifications and content in this manual may be changed without prior notification Reproduction of this manual without prior permission is prohibited All r...

Page 32: ...ce tw idec com Hong Kong IDEC Izumi H K Co Ltd Tel 852 2803 8989 info hk idec com China Shanghai IDEC Shanghai Corporation Tel 86 21 6135 1515 idec cn idec com China Shenzen IDEC Shenzen Corporation T...

Page 33: ...B 1968 0...

Reviews: