WindO/I-NV4 User’s Manual
15-5
1 Overview
15
Op
era
tio
n L
og
F
un
ctio
n
7. Event Name:
When the recorded data is output as a CSV file, this is the text displayed as a label to
describe the event that occurred. This item is configured in the Data Labels dialog box.
8. Part Name:
The part name for the pressed touch switch when the
Press buttons
event occurs.
9. Device Address:
The destination device address when the
Write Data to any Device Addresses
event
occurs.
When an indirect write is used, the device address specified by the indirect value is recorded.
Example: When the device address configured as the destination for the value 100 is LDR100
and the indirect value is 3
10. Changed to:
The result produced from the event that occurred. The recorded content varies based on the
event that occurred.
Switch to Base Screen: The screen type and number after switching.
Base
n
:
Base screen (
n
: screen number)
Example: Base 1
Change Users:
The user name after the change.
Change Operation Modes: The operation mode after the change.
Run Mode:
Run Mode
System Mode: System Mode
Monitor Mode: Monitor Mode
Offline Mode: Offline Mode
Write Data to any Device Addresses:
The value written to the device address by pressing the touch
switch. This value is handled as UBIN16(W). For details, refer to
Chapter 2 “1.1 Available Data” on page 2-1.
The value written to the device address is recorded as UBIN16(W)
regardless of the data type.
Example: When -10 (0xFFF6) is written to device address D0
If the written value is 2 words (32 bits), each word is recorded (16
bits). For the storage order for 32-bit device address data, the
upper word and lower word are stored following the
Storage
Method of 32-bit Numerical Data for Internal Devices
or the
Storage Method of 32-bit Numerical Data
setting. For details,
refer to Chapter 4 “Storage Method of 32-bit Numerical Data for
Internal Devices” on page 4-29 and Chapter 4 “Storage Method of
32-bit Numerical Data” on page 4-48.
Example: The
from Lower word
is selected as the
Storage
Method of 32-bit Numerical Data
in the
Communication Driver
tab on the Project Settings
dialog box and 12345678 (0xBC614E) is written to device
address D0 with the data type UBIN32(D).
Event Name
Part Name
Details
Changed to
Press buttons
WordSwitch1
‒
‒
Write Data to any Device Addresses
‒
LDR103
100
Changed to
Details
Part Name
Press buttons
WordSwitch1
Write Data to
any Device Addresses
‒
‒
‒
D0
65526 (0xFFF6)
Event Name
Event Name
Press buttons
WordSwitch1
Write Data to
any Device Addresses
‒
D0
24910 (0x614E)
Write Data to
any Device Addresses
‒
D1
188 (0xBC)
Changed to
Details
Part Name
‒
‒
Summary of Contents for WindO/I-NV4
Page 1: ...B 1701 16 User s Manual...
Page 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Page 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Page 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Page 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Page 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Page 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Page 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Page 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Page 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Page 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Page 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Page 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Page 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Page 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Page 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Page 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...