Select the condition to transmit data in
Trigger Type
under
Trigger Condition
from the following.
■
Rising-edge
Data is transmitted when the value of device address changes from 0 to 1.
Specify the bit device or the bit number of the word device as the condition.
Click
to display the Tag Editor. For the device address configuration procedure, refer to Chapter 2 “5.1 Device
Address Settings” on page 2-70.
■
Falling-edge
Data is transmitted when the value of device address changes from 1 to 0.
Specify the bit device or the bit number of the word device as the condition.
Click
to display the Tag Editor. For the device address configuration procedure, refer to Chapter 2 “5.1 Device
Address Settings” on page 2-70.
■
Satisfy the condition
Data is transmitted when condition changes from not satisfied to satisfied.
Specify the conditional expression in
Condition
and select the data type handled by the conditional expression in
Data Type
.
Click
to display the Trigger Condition Settings dialog box. For the conditional expressions configuration
procedure, refer to Chapter 2 “5.2 Setting Conditional Expressions” on page 2-73.
For details on data types, refer to Chapter 2 “1.1 Available Data” on page 2-1.
■
Fixed Period
Data is transmitted at a fixed time interval.
Set the time interval between data transmissions as 1 to 3600 (seconds) in
Period (sec)
.
11
Specify the bit device or the bit number of the word device for reporting that data transmission was successfully
completed in
Completed Device Address
under
Detail
.
Click
to display the Tag Editor. For the device address configuration procedure, refer to Chapter 2 “5.1 Device
Address Settings” on page 2-70.
12
Specify the destination word device for the transmitted data size and error information in
Status Device Address
under
Detail
.
Click
to display the Tag Editor. For the device address configuration procedure, refer to Chapter 2 “5.1 Device
Address Settings” on page 2-70.
13
Specify the wait time (0 to 255) from when the trigger condition is satisfied to when the data is transmitted in
Transmission Wait (x100 msec)
under
Detail
.
14
Enter a comment for transmission command in
Comment
under
Detail
.
The maximum number is 40 characters.
Summary of Contents for WindO/I-NV4
Page 1: ...B 1701 16 User s Manual...
Page 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Page 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Page 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Page 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Page 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Page 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Page 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Page 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Page 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Page 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Page 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Page 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Page 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Page 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Page 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Page 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...