3 Sound Settings Dialog Box
21-8
WindO/I-NV4 User’s Manual
■
Change Volume Level
Adjust the volume (0 to 31) of sound files and movie files played by the MICRO/I.
The volume changes according to the value of the specified Device Address.
The sound is muted when the Device Address value is 0, and the volume is maximum when the value is 31 or out of range.
Enter the Device Address in the text box or click
to specify the address in the displayed Tag Editor. For the device
address configuration procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-70.
■
Enable Mute
Mute the volume of sound files and movie files played by the MICRO/I.
When the value of the specified Device Address is 1, the sound is muted.
When the sound is muted while a sound file is playing, it continues playing without making a sound.
Enter the Device Address in the text box or click
to specify the address in the displayed Tag Editor. For the device
address configuration procedure, refer to Chapter 2 “5.1 Device Address Settings” on page 2-70.
●
Individual Settings
Dialog Box
Register or change the settings of the selected ID.
■
ID
Shows the Sound ID (1 to 1024) of the sound file to be played.
If the
Individual Settings
dialog box is opened with multiple IDs selected in
Settings
,
ID
number will not be
displayed.
■
File Name
Specify the sound file.
Click the
button to display the
Open
dialog box. Then specify a sound file with the
Open
dialog box.
If the
Individual Settings
dialog box is opened with multiple IDs selected in
Settings
,
File Name
will not be
displayed.
■
Save To
Select the location to save the sound file to as
Internal Memory
or
External Memory Device
*1 USB flash drive inserted in USB1 for HG2J-7U, SD memory card for HG5G/4G/3G-V and HG4G/3G
*2 HG5G/4G/3G-V, HG4G/3G only
When the
Change Volume Level
check box is cleared, MICRO/I plays sound files and movie files at
maximum volume.
Summary of Contents for WindO/I-NV4
Page 1: ...B 1701 16 User s Manual...
Page 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Page 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Page 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Page 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Page 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Page 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Page 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Page 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Page 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Page 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Page 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Page 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Page 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Page 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Page 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Page 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...