3 Security Dialog Box
23-44
WindO/I-NV4 User’s Manual
●
Options
Tab
■
Use Password to open a Project
Select this check box and enter a password to protect the project with a dedicated password when opening it.
The number for the password is 4 to 15 characters. Only alphanumeric characters and symbols can be used.
The operations subject to password protection are as follows.
• Opening projects
• Reusing screens
• Opening projects after uploading project data
■
Change User by Device Address
Select this check box to switch the user account according to the value of device address.
The user account is specified by using the number on the
General
tab.
Example: When the trigger device address is D0 and the default user is selected as User1
The user account switches according to the value of device address.
Confirm Password:
Re-enter the password that was entered in
Use Password to open Project
.
Write down the password so you do not forget it and save that note in a safe place.
(Trigger Device Address): Specifies the word device to write the number.
Click
to display the Tag Editor. For the device address configuration procedure, refer to
Chapter 2 “5.1 Device Address Settings” on page 2-70.
1
2
3
No.
User Name
User3
User2
User1
(Default user)
0
User account
Trigger device address
D0 value
Switch to default
user account
1
Switch to user
account no. 1
2
Switch to user
account no. 2
3
Switch to user
account no. 3
4
None
Action
User3
User3
User2
User1
User1
The user account is not switched when the value of
device address is a number not configured to a user
account or an invalid number.
If the value of device address is
0, the user is switched to the
default user.
Summary of Contents for WindO/I-NV4
Page 1: ...B 1701 16 User s Manual...
Page 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Page 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Page 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Page 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Page 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Page 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Page 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Page 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Page 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Page 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Page 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Page 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Page 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Page 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Page 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Page 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...