1 Monitoring with WindO/I-NV4
25-6
WindO/I-NV4 User’s Manual
●
Screen Monitor
Automatically displays device addresses used on the screen displayed on the MICRO/I. Enables values of device
addresses to be monitored and changed.
■
Device Address
Displays the device addresses used on the screen displayed on the MICRO/I.
next to
Comment
toggles between showing and hiding comments. When comments are displayed, click to
display a popup menu, then click
Comment
and select the check box.
■
Comment
Displays comments on device addresses saved in Tag Editor. Comments are displayed only after you click next to
Device Address
to display a popup menu, then click
Comment
and select the check box.
■
Data Type
Selects the data format of the displayed value. For details, refer to Chapter 2 “1.1 Available Data” on page 2-1.
■
Words
Specify the number of word devices (1 to 16) stored the display value. 2 single-byte characters can be displayed by 1
word.
This option can only be configured
String(Western)
,
String(Japanese)
,
String(Simplified Chinese)
,
String(Traditional Chinese)
,
String(Hangul)
,
String(Central European)
,
String(Baltic)
,
String(Cyrillic)
is
selected as Data Type.
The storage order for word device address data is set according to
Storage Method of String Data
on the
System
tab in the
Project Settings
. For details, refer to Chapter 4 “Storage Method of String Data” on page 4-29.
■
Value
Enables values of device addresses to be display and changed. The value range depends on the data type. For details,
refer to Chapter 2 “1.1 Available Data” on page 2-1.
■
Hexadecimal, Binary
Displays the current value of device address in hexadecimal and binary format. To change a value, double-click a cell
and then specify a value.
The value range depends on the data type. For details, refer to Chapter 2 “1.1 Available Data” on page 2-1.
Comments are displayed only after you click next to
Value
to display a popup menu and then select the
HEX
and
BIN
check box.
UBIN16(W)
,
BIN16(I)
,
UBIN32(D)
,
BIN32(L)
,
BCD4(B)
,
BCD8(EB)
,
Float32(F)
:
Displays the current value of device address in decimal format. To change a value, double-click a cell and then
enter a value.
The value range depends on the data type. For details, refer to Chapter 2 “1.1 Available Data” on page 2-1.
Click to toggle display of
HEX
and
BIN
format. To display
HEX
and
BIN
values, click to display a popup
menu, then click
HEX and BIN
and select the check box.
String(Western)
,
String(Japanese)
,
String(Simplified Chinese)
,
String(Traditional Chinese)
,
String(Hangul)
,
String(Central European)
,
String(Baltic)
,
String(Cyrillic)
:
Displays the current value of device address in string. To change a value, double-click a cell and then enter the
messages in the language selected.
Summary of Contents for WindO/I-NV4
Page 1: ...B 1701 16 User s Manual...
Page 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Page 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Page 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Page 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Page 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Page 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Page 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Page 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Page 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Page 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Page 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Page 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Page 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Page 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Page 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Page 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...