WindO/I-NV4 User’s Manual
25-27
2 Monitoring on the MICRO/I
25
M
on
ito
r F
un
ctio
n
2.3 Change Values of Device Addresses and Check the Operation of Project Data Offline
Offline mode allows you to change values of device addresses and to check the operation of project data on the
MICRO/I unit only. By possessing virtualized external device addresses inside the MICRO/I, you can efficiently debug
using the Device Monitor function.
●
Switching to Offline Mode
1
Press the upper-left corner of the screen on the MICRO/I for three seconds or more.
The Maintenance Screen is displayed.
2
Press
System Mode
.
The MICRO/I switches to the Top Page of the System Mode.
3
Press
Offline
.
The MICRO/I switches to offline mode and “Offline Mode” is displayed at the bottom left of the screen.
4
Monitor and change the values of device addresses with Device Monitor to check the operation of project data.
If there are any errors, edit the project data with WindO/I-NV4, and then download the edited project data to the
MICRO/I.
To exit offline mode, switch to System Mode with the operations in steps
1
and
2
, and then press
Run
on the Top
Page.
Press and hold 3
or more seconds
MICRO/I
Maintenance
System Mode
Device Monitor
Adjust Brightness
If a password has been configured for the project data, the Enter Password screen will be displayed. Select
a user name and then enter a password. For details, refer to Chapter 23 “User Accounts and the Security
Run
Offline
Main Menu
<<
>>
BRIGHTNESS 31
MAC Address 00:03:7B:F0:12:A8
IP Address 192.168.0.1(DHCP)
2010/OCT/14/THU 14:56:44
IDEC HG G SERIES
SYSTEM MODE TOP PAGE
ENG/JPN
Summary of Contents for WindO/I-NV4
Page 1: ...B 1701 16 User s Manual...
Page 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Page 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Page 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Page 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Page 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Page 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Page 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Page 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Page 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Page 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Page 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Page 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Page 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Page 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Page 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Page 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...