WindO/I-NV4 User’s Manual
28-35
3 FTP Client Function
28
M
ain
te
na
nc
e
• Files cannot be copied or moved from the FTP server to the FTP server.
• When transferring files from external memory to external memory and HMI special internal relay LSM67 is
0, subfolders can be copied and moved up to five folders deep. When HMI special internal relay LSM67 is
changed from 0 to 1, subfolders cannot be copied or moved.
• Path delimiters and characters in the folder path configured by
Fixed
or
Specify the Location by
Value of Device Address
that cannot be used vary based on the model.
• Folder path that exceed the limits in
Specify the Location by Value of Device Address
and folder or
file path configured with characters that cannot be used are as follows.
- When the text of the folder or file path exceeds the maximum number of device addresses (no NULL),
the text stored in device addresses up to the maximum number of device addresses from the start is
configured.
- When a character that cannot be used is set, the text is up to that character.
• If the transfer destination is a MICRO/I configured as an FTP server, "A + delimiter" or "B + delimiter"
must be specified at the beginning of the path for each type of external memory. Path delimiters vary
based on the model.
Example 1: If the transfer destination is the “ALARMLOG” folder in the “HGDATA01” folder on the USB
flash drive inserted in USB2 for HG2J-7U:
B/HGDATA01/ALARMLOG
Example 2: For HG5G-V, if the transfer destination is the “ALARMLOG” folder in the “HGDATA01” folder
on the SD memory card:
A
\
HGDATA01
\
ALARMLOG
Model
HG2J-7U
HG5G/4G/3G/2G-V, HG4G/3G, HG2G-5F/-5T, HG1G/1P
Delimiter
Characters that cannot be used
" # $ & ' ( ) * : ; < > ? \ ` | ~
" * : ; < > ? |
/
\
Summary of Contents for WindO/I-NV4
Page 1: ...B 1701 16 User s Manual...
Page 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Page 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Page 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Page 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Page 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Page 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Page 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Page 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Page 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Page 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Page 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Page 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Page 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Page 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Page 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Page 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...