5 User Communication
3-46
WindO/I-NV4 User’s Manual
■
Data List
Shows a list of command data. Double clicking the line displays the Data Settings dialog box.
For details, refer to “Data Settings Dialog Box” on page 3-48. The maximum data size that can be configured is 1500
bytes per command.
The content displayed in lists varies based on the type of command.
Constant (Character):
Displays the specified data enclosed in " ".
"Data"
Example: "1234"
Constant (Hexadecimal):
Displays the specified data with each byte value enclosed in ' '.
'Data of the first byte' 'Data of the second byte' 'Data of the third byte' 'Data of the forth byte'
Example: '31' '32' '33' '34'
Device Address:
Displays the specified data enclosed by < >, in the following order.
<Device Address Conversion Type Number of bytes Variable Words Storage Method of data>
Device Address:
Displays the device address enclosed by [ ]
When the
Use Reference Device Address
check box is selected, displays as
OFFSET([Device Address], [Reference Device Address])
Number of bytes:
Displays the number of bytes of the transmitted or received data.
Conversion Type:
Display the conversion methods for values of device addresses as follows.
The Conversion Type varies based on the type selected in
Type
on the
Command Settings dialog box.
TXD: HEX-A:
DEC-A:
N:
Hexadecimal to ASCII
is selected
Decimal to ASCII
is selected
No conversion
is selected
RXD: A-DEC:
A-HEX:
N:
ASCII to Decimal
is selected
ASCII to Hexadecimal
is selected
No conversion
is selected
Variable:
When the
Variable
check box is selected, variables are displayed as follows.
V00:
NULL(00h)
is selected for transmission command
V [Device Address]:
Device Address
is selected for transmission command
V: In the case of receive command
Words:
Displays the number of word devices for transmitting or receiving data.
Storage Method of data: Displays the handling method for value of read device address as follows.
U:
from Upper byte
is selected
L:
from Lower byte
is selected
Example: <OFFSET([LDR0100], [LDR0300]) N 2V[LDR0200] 2 U>
Registering Constant (Character):
Displays the specified data enclosed in << >>.
<<Index No. of No. 1: Data of No. 1 Index No. of No. 2: Data of No. 2 ... Index No. of No. N: Data of No.
N Index Device Address>> (N = 1 to 100)
Data:
Displays the data enclosed by " "
Index Device Address: Displays the device address enclosed by [ ]
Example: <<1:"123" 2 :"456" 3 :"789" [LDR0100]>>
Registering Constant (Hexadecimal):
Displays the specified data enclosed in << >>.
<<Index No. of No. 1: Data of No. 1 Index No. of No. 2: Data of No. 2 ... Index No. of No. N: Data of No.
N Index Device Address>> (N = 1 to 100)
Data:
Displays the data enclosed by ' '
Index Device Address: Displays the device address enclosed by [ ]
Example: <<1:'313233' 2:'343536' 3 :'373839' [LDR0100]>>
Summary of Contents for WindO/I-NV4
Page 1: ...B 1701 16 User s Manual...
Page 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Page 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Page 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Page 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Page 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Page 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Page 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Page 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Page 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Page 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Page 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Page 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Page 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Page 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Page 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Page 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...