3 Settings
34-10
WindO/I-NV4 User’s Manual
●
Communication I/F (Comm. I/F)
From the Main Menu screen, press
Initial Setting (Initial Setting),
and then
Communication I/F (Comm. I/F)
to display the communication interface settings menu screen.
You can use this screen to set the items below. Press the button for each item to set.
■
Serial 1
Allows the setting of communication parameters for the Serial Interface 1.
From the Main Menu screen, press
Initial Setting, Communication I/F
, and then
Serial 1
.
■
Serial 2
Allows the setting of communication parameters for the Serial Interface 2. For the HG5G/4G/3G/2G-V, RS232C and
RS422/485 can be set individually.
From the Main Menu screen, press
Initial Setting, Communication I/F
, and then
Serial 2
.
■
Serial 3
Allows the setting of communication parameters for the Serial Interface 3.
From the Main Menu screen, press
Initial Setting, Communication I/F
, and then
Serial 3
.
■
(RS232C)
Allows the setting of communication parameters for the Serial Interface (SERIAL1) (RS232C).
From the Main Menu screen, press
(Initial Setting), (Comm. I/F),
and then
(RS232C)
.
■
(RS422/485)
Allows the setting of communication parameters for the Serial Interface (SERIAL1) (RS422/485).
From the Main Menu screen, press
(Initial Setting), (Comm. I/F),
and then
(RS422/485)
.
■
Ethernet IP Address (IP Address)
Use the following procedure to set the IP address and Subnet mask settings.
From the Main Menu screen, press
Initial Setting (Initial Setting), Communication I/F (Comm. I/F),
and
then
Ethernet IP Address (IP Address)
.
Press the left/right buttons to select an item, then use the Keypad to enter the IP address and subnet mask values.
Press
SAVE (SAVE)
to save the settings.
■
Ethernet Default Gateway (Default Gateway)
Specify the default gateway.
From the Main Menu screen, press
Initial Setting (Initial Setting), Communication I/F (Comm. I/F),
and
then
Ethernet Default Gateway (Default Gateway)
.
Press the left/right buttons to select an item, then use the Keypad to enter the default gateway value.
Press
SAVE (SAVE)
to save the settings.
• To return to the initial settings screen, press
Init Set (Init Set)
at the top of the screen.
• Press
Comm. I/F (Comm. I/F)
at the top of the screen to return to the communication interface
settings menu.
HG3G
HG2G-5F
HG5G-V HG4G-V
HG3G-V
HG2G-V
HG2G-5T
HG4G
HG1G HG1P
HG2J-7U
HG3G
HG2G-5F
HG5G-V HG4G-V
HG3G-V
HG2G-V
HG2G-5T
HG4G
HG1G HG1P
HG2J-7U
HG3G
HG2G-5F
HG5G-V HG4G-V
HG3G-V
HG2G-V
HG2G-5T
HG4G
HG1G HG1P
HG2J-7U
HG3G
HG2G-5F
HG5G-V HG4G-V
HG3G-V
HG2G-V
HG2G-5T
HG4G
HG1G HG1P
HG2J-7U
HG3G
HG2G-5F
HG5G-V HG4G-V
HG3G-V
HG2G-V
HG2G-5T
HG4G
HG1G HG1P
HG3G
HG2G-5F
HG5G-V HG4G-V
HG3G-V
HG2G-V
HG2G-5T
HG4G
HG1G HG1P
HG2J-7U
The setting is not updated if you display another screen before applying the setting.
The setting is not updated if you display another screen before applying the setting.
Summary of Contents for WindO/I-NV4
Page 1: ...B 1701 16 User s Manual...
Page 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Page 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Page 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Page 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Page 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Page 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Page 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Page 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Page 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Page 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Page 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Page 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Page 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Page 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Page 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Page 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...