WindO/I-NV4 User’s Manual
8-157
8 Selector Switch
8
Bu
tto
ns
■
Visible Condition
The Selector Switch is displayed while the condition is satisfied. The Selector Switch is hidden while the condition is
not satisfied.
Example: When
Trigger Type
is
While ON
and
Device Address
is
LM0
While LM0 is 0, the condition is not satisfied and the Selector Switch is hidden.
While LM0 is 1, the condition is satisfied and the Selector Switch is displayed.
While OFF:
Enables the Selector Switch when the value of device address is 0.
While satisfying the condition: Enables the Selector Switch when the condition is satisfied.
Data Type:
Selects the type of data handled by the conditional expression for the input condition.
This option can only be configured if
While satisfying the condition
is selected for
Trigger Type
.
For details, refer to Chapter 2 “1.1 Available Data” on page 2-1.
Device Address: Specifies the bit device or the bit number of the word device to serve as the input condition.
This option can only be configured when
While ON
or
While OFF
is selected for
Trigger Type
.
Click
to display the Tag Editor. For the device address configuration procedure, refer to Chapter 2
“5.1 Device Address Settings” on page 2-70.
Condition:
Specifies the conditional expression for the input condition.
This option can only be configured when
While satisfying the condition
is selected for
Trigger
Type
.
Click
to display the
Trigger Condition Settings
dialog box. For the conditional expression
configuration procedure, refer to Chapter 2 “5.2 Setting Conditional Expressions” on page 2-73.
Comment:
Used for entering a comment for the input condition. The maximum number is 80 characters.
1
0
Enabled
Disabled
Value of
device address
Selector
Switch state
Disabled
Disabled
Enabled
Enabled
Selector
Switch state
Disabled
Disabled
Disabled
Enabled
Enabled
Enabled
Satisfied
Not satisfied
Condition
LM0:
MICRO/I
0
LM0: 1
Show
Condition
Not
satisfied
Condition
Satisfied
Hide
If a hidden Selector Switch is redisplayed on the screen when
Read from Destination Device Address
is
selected for
Default Position
on the
General
tab, the display position of the knob changes according to
the value of the device address configured for the channel. When
Ch1
,
Ch2
, or
Ch3
is selected, the knob is
displayed at the same position as before it was hidden, regardless of the value of device address configured
for the channel.
Summary of Contents for WindO/I-NV4
Page 1: ...B 1701 16 User s Manual...
Page 108: ...5 WindO I NV4 Common Operations and Settings 2 76 WindO I NV4 User s Manual...
Page 256: ...7 BACnet Communication 3 148 WindO I NV4 User s Manual...
Page 372: ...6 Screen Restrictions 5 32 WindO I NV4 User s Manual...
Page 390: ...5 Part Library Function 6 18 WindO I NV4 User s Manual...
Page 420: ...3 Text 7 30 WindO I NV4 User s Manual...
Page 628: ...2 Multi State Lamp 9 34 WindO I NV4 User s Manual...
Page 924: ...4 Meter 11 76 WindO I NV4 User s Manual...
Page 990: ...7 Timer 12 66 WindO I NV4 User s Manual...
Page 1030: ...4 Using Data and Detected Alarms 13 40 WindO I NV4 User s Manual...
Page 1098: ...4 Using the Data 15 22 WindO I NV4 User s Manual...
Page 1248: ...5 Restrictions 22 18 WindO I NV4 User s Manual...
Page 1370: ...2 Monitoring on the MICRO I 25 28 WindO I NV4 User s Manual...
Page 1388: ...4 Restrictions 26 18 WindO I NV4 User s Manual...
Page 1546: ...5 Module Configuration Dialog Box 30 36 WindO I NV4 User s Manual...
Page 1614: ...3 Settings 34 14 WindO I NV4 User s Manual...
Page 1726: ...5 Text Alignment A 10 WindO I NV4 User s Manual...